These instructions must be read and understood completely before attempting installation.
Signal Words on Product Labeling
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE Signal Words in Manuals
The signal words DANGER, WARNING, CAUTION, and NOTE The signal word WARNING isused throughout this manual inthe
are used to identify levels of hazard seriousness. The signal word following manner:
DANGER is only used on product labels to signify an immediate
hazard. The signal words WARNING, CAUTION, and NOTE will
be used on product labels and throughout this manual and other The signal word CAUTION is used throughout this manual in the
manual that may apply to the product, following manner:
DANGER - Immediate hazards which will result in severe person-
at injury or death.
WARNING - Hazards or unsafe practices which could result in
severe personal injury or death.
Signal words are used in combination with colors and/or pictures
CAUTION - Hazards or unsafe practices which may result in or product labels.
minor personal injury or product or property damage.
NOTE - Used to highlight suggestions which wilt result in en- z_ Safety-alert symbol
hanced installation, reliability, or operation. When you see this symbol on the unit and in instructions or manu-
als, be alert to the potential for personal injury.
TABLE OF CONTENTS
DIMENSIONS ............................................... 3
SAFETY CONSIDERATIONS .................................. 3
INTRODUCTION ............................................ 4
CODES AND STANDARDS ................................... 5
SAFETY ................................................ 5
GENERAL INSTALLATION ................................ 5
COMBUSTION AND VENTILATION AIR ..................... 5
DUCT SYSTEMS ........................................ 5
ACOUSTICAL LINING AND FIBROUS GLASS DUCT ......... 5
GAS PIPING AND GAS PIPE PRESSURE TESTING .......... 5
ELECTRICAL CONNECTIONS ............................ 5
VENTING .............................................. 5
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS ........... 5
LOCATION ................................................. 6
AIR FOR COMBUSTION AND VENTILATION .................... 7
INSTALLATION .............................................. 10
UPFLOW INSTALLATION ................................. 10
DOWNFLOW INSTALLATION ............................. 11
FILTER ARRANGEMENT ................................. 12
AIR DUCTS ............................................. 13
AIR DELIVERY - CFM .................................... 14
ELECTRICAL CONNECTIONS ............................ 20
115-V WIRING .......................................... 20
J-BOX RELOCATION .................................... 20
ELECTRICAL CONNECTION TO J-BOX .................... 20
ELECTRICAL DATA ...................................... 21
24-V WIRING ........................................... 22
ACCESSORIES ......................................... 22
VENTING .................................................. 23
GENERAL VENTING REQUIREMENTS ..................... 23
MASONRY CHIMNEY REQUIREMENTS .................... 24
APPLIANCE APPLICATION REQUIREMENTS ............... 26
ADDITIONAL VENTING REQUIREMENTS .................. 26
SIDEWALL VENTING .................................... 27
START-UP, ADJUSTMENT, AND SAFETY CHECK ............... 30
GENERAL .............................................. 30
START-UP PROCEDURES ............................... 30
ADJUSTMENTS ......................................... 31
SPEED SELECTION ..................................... 32
CHECK SAFETY CONTROLS ............................. 33
CHECKLIST ............................................ 34
ORIFICE SIZE AND MANIFOLD PRESSURE ................ 35
SERVICE AND MAINTENANCE PROCEDURES ................. 39
CARE AND MAINTENANCE ................................... 39
SEQUENCE OF OPERATION ................................. 43
WIRING DIAGRAM .......................................... 44
TROUBLESHOOTING GUIDE ................................. 45
IS09001
Use of the AHRI Certified TM Mark indicates
a manufacturer's participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning could
result in equipment malfunction, property damage,
3ersonal injury and/or death.
Installation or repairs made by unqualified persons
could result in equipment malfunction, property
damage, personal injury and/or death.
The information contained in this manual is intended for
use by a qualified service technician familiar with safety
3rocedures and equipped with proper tools and test
instruments.
Installation must conform with local building codes and
with the Natural Fuel Gas Code (NFCG) NFPA
54/ANSI Z223.1, and National standards of Canada
CAN/CSA-B149.1 and .2 Natural Gas and Propane
Installation Codes.
INSTALLER: Affix these instructions on or adjacent tothe furnace.
CONSUMER: Retain these instructions for future reference.
Portionsof the text andtables are reprintedfrom NFPA 54/ANSI Z223.t -20096), with permission of National Fire Protection Association, Quincy, MA 02269 and American Gas Association, Washing-
ton, DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI, on the referenced subiect, which is represented only by the standard in itsentirety,
PrintedinU.S.A. 441 01 1402 02 May. 2012
Question and Answer IconNeed help?

Do you have a question about the Kenmore N8MSL0701412A1 and is the answer not in the manual?

Kenmore N8MSL0701412A1 Specifications

General IconGeneral
BrandKenmore
ModelN8MSL0701412A1
CategoryFurnace
LanguageEnglish

Summary

Safety Labeling and Signal Words

General Warnings and Cautions

Safety Considerations Overview

Highlights critical safety hazards including fire, explosion, electrical shock, and CO poisoning.

Installation Guidelines

Codes and Standards Compliance

Electrostatic Discharge (ESD) Precautions

Location and Air Requirements

Specific Installation Warnings

Garage Installation Hazard

Warning about installing furnace in a residential garage.

Furnace Mounting Position Warning

Warning about not installing furnace on its back or hanging it.

Combustion Air Methods

Furnace Corrosion Hazard

Caution about contaminated air causing furnace damage.

Carbon Monoxide Poisoning Hazard

Warning about negative pressure conditions affecting furnace.

Installation Orientations and Air Inlets

Downflow Installation

Horizontal Installation

Horizontal Installation Hazards

Warning about horizontal installation hazards.

Filter Arrangement

Filter Installation Warning

Warning about operating furnace without an air filter.

Air Duct Requirements

Gas Piping and Connections

Gas Piping Installation Warning

Warning about gas piping installation and leak testing.

Electrical Connections and Wiring

Electrical Shock and Grounding Hazards

Warnings about electrical shock, grounding, and wiring errors.

Disconnect Switch Mounting Warning

Specific safety warning for mounting disconnect switch.

Specific Wiring Installations

Control Wiring and Accessories

Venting Requirements and Hazards

Carbon Monoxide Hazard in Venting

Steps to follow for safe appliance venting and operation.

Masonry Chimney Requirements

Appliance Application and Venting

Carbon Monoxide Hazard and Corrosion

Warning about contaminants causing corrosion in furnaces.

Venting Hazards and Sidewall Venting

Burn Hazard - Hot Vent Pipes

Caution about hot vent pipes being accessible to children.

Start-Up, Adjustment, and Safety Check

Fire Hazard - Limit Switches

Warning about manual reset limit switches and combustion air.

Start-Up Procedures - Gas Leak Testing

Warning about testing gas lines for leaks.

Specific Hazards and Cautions

Electrical Shock Hazard - Blower Door Switch

Warning about blower access door switch and manual closing.

Furnace Damage Hazard - Orifice Redrilling

Caution about redrilling orifices and its consequences.

Electrical Shock Hazard - Speed Tap Change

Warning about disconnecting power before changing speed tap.

Furnace Overheating Hazard - Temperature Rise

Caution about adjusting fan speed for proper temperature rise.

Safety Controls Check

Installation Checklist

Service and Maintenance Procedures

General Maintenance Hazards

Warnings related to performing maintenance without proper skills or safety measures.

Component Maintenance Procedures

Furnace Storage Hazards

Warning about storing flammable items near the furnace.

Electrical Safety During Maintenance

Warning about turning off gas/electrical supplies and lockout.

Heat Exchanger Cleaning and Gas Piping Warnings

Unit Damage Hazard - Temperature Rise

Caution about adjusting fan speed for proper temperature rise.

Gas Piping Testing Warning

Warning about testing gas lines with open flame.

Sequence of Operation and Troubleshooting

Troubleshooting Flowchart

Parts Information and Model Identification

Related product manuals