EasyManua.ls Logo

Kenwood KDC-8021 - Page 7

Kenwood KDC-8021
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KDC-8021/M9021/X859
7
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin Name I/O Purpose Processing Operation
Processing During Processing During
Non-Operation STBY
1 MC-DATA I/O
DATA line to Panel
uCOM.
Hi-Z Hi-Z
2 MC-CLK O CLK line to Panel uCOM.
Panel attached: "H".
Detached: "Hi-Z".
H
3 PLL-DATA I/O DATA I/O to/from F/E. Hi-Z Hi-Z
4 PLL-CLK I/O CLK I/O to/from F/E. Hi-Z Hi-Z
5 AM+B I/O
AM power supply
terminal.
During AM operation: "H". Hi-Z Hi-Z
During FM operation: "H".
6 FM+B I/O FM power supply terminal. With RDS and RBDS Hi-Z Hi-Z
only, last FM: "H".
7 CH-CON O CH control output. ON:H OFF: L L L
Normally "H". In recovery
8 CH-RST O CH reset output.
after system RST,
remains H for 400 ms
LL
then goes L"
9 Evdd -
Positive power supply
terminal.
10 Evss - GND terminal.
During FM seek and
Last FM with RDS
11 AFS O
Time constant switching
AM search: L.
and RBDS: "H".
upon noise detection.
During reception; H.
Without RDS and
L
RBDS: "L".
12 BEEP O Beep output terminal. L L
Since there is no
13 REMO I
Wired remote input
wired remote control,
terminal.
connected to GND.
14 N.C O Output Open. Not used. L
15 N.C O Output Open. Not used. L
16 IC2-SDA I/O
IC2, IC5 and CD
mechanism DATA line.
Hi-Z Hi-Z
17 IC2-SCL I/O
IC2, IC5 and CD
mechanism CLOCK line.
Hi-Z Hi-Z
"L" when M MUTE R is
L (during CD playback).
"H" (other sources
18 PRE-MUTE R O PREOUT(Rch)MUTE "L" during momentary
than CD)
H
power down. "H" only in
2-zone operation.
"L" when M MUTE R is
L (during CD playback).
19 PRE-MUTE L O PREOUT(Lch)MUTE "L" during momentary
H (other sources
H
power down. "H" only in
than CD)
2-zone operation.
20 N.C O Output Open. Not used. L
21 TEST - Test pin. Normal: "L". During
22 N.C(SVR) O
power OFF: "H" in 5 sec. "H" ("L" in 5 sec.
Power OFF: H after Power OFF).
23 P-MUTE O Power IC MUTE terminal.
Power OFF: L All OFF: "L ("H" in 5 sec.
"L". Tel muting: "L"
H
after P-ON OFF).
POWER IC ON: H
24 P-STBY O Power IC STBY terminal. POWER IC OFF : L L L
ALL OFF: H
ON: Open. OFF: "L".
25 MUTE O Muting terminal. Time constant: 0.48 ms L
Open ("H" in 5 sec.
(with both ON/OFF)
after P-ON OFF).
SYSTEM MICROCOMPUTER uPD703033AGF-***-3BA (X25)