(No.RA018<Rev.002>)1-85
[Analog
Narrow]
1) Adj item:
[An MSK]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[MSK Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Pan-
el tun-
ing
mode]
[],
[]
[PC
test
mode]
[],
[]
Write the value as fol-
lowings. 513 (Reference
value)
1.50kHz±0.05
kHz
17.
CWID
Devia-
tion *3
[Analog
Narrow]
1) Adj item:
[An CWID]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[CWID Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Pan-
el tun-
ing
mode]
[],
[]
[PC
test
mode]
[],
[]
Write the value as fol-
lowings. 513 (Reference
value)
1.00kHz±0.10
kHz
*3: Refer to the “4.19.1 Necessary Deviation adjustment item for each signaling and mode” table.
18.
Battery
Warning
Level
writing
1) Adj item:
[BATT]
Adjust:[***]
PTT: ON
1) Adj item:
[Battery Warning
Level]
Press [Transmit]
button.
Power
meter
DVM
Panel ANT
BATT
termi-
nal
Press the PTT switch or
[Transmit] button on the
PC window. Apply 6.20V
to battery terminal. Con-
firm that one pre-deter-
mined numeric in the
range 1 to 256 appears.
[Panel tuning mode]
Press [ ] key to store
the adjustment value.
[PC test mode]
Press [Apply] button to
store the adjustment val-
ue.
Item Condition Measurement Adjustment Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 F3 and is the answer not in the manual?

Kenwood NX-5200 F3 Specifications

General IconGeneral
Frequency Range136-174 MHz
Number of Channels1024
Waterproof RatingIP67
Operating Temperature-30°C to +60°C
Digital ModeNXDN, DMR
Analog ModeFM
Channel Spacing25 kHz
Power Output5W
RF Output Power5W
Digital ProtocolNXDN
Modulation16K0F3E
Operating Voltage7.5 V DC

Related product manuals