37
• Yourhobisdesignedtobeinstalledonthestandardcounterswhichyoumayfindinthemarket.
• Thematerialsusedonthesurfaceandtheconnectionsunderthecountershouldberesistantagainst
minimum100°Ctemperature.
• Asafedistanceshouldbeleftbetweenthehobandthecounterwalls(Figure4).
• Theholetobeprovidedforthehobonthecountershouldbeasperthefigure.(Figure4)
• Thedistancebetweenthehobbottomandanysurfacesbeneathshouldbeatleast25mm.(Figure5)
• Thedistancebetweenthecooktopadanotherdevice(e.g.kitchenhood)shall
notbelessthan700mm(Figure5).
• If60cmHobswillbeplaceonabuiltinovenwithoutanycoolingsystem,
itisrecommendedtoleave300cm²ofventilationholeinordertoensureair
circulation.If75or90cmhobwillbeplaced,theovenhastohaveacooling
fan.
Figure4
Figure5