1. Cooktop
2. Aspirator
3. Electricalventilator
4. VentilationOpening

In order to prevent insertion of particles and liquids
betweenthehobandthecounterattachthegasketon
thehobwithoutallowinganyoverlappingbeforethe
installation.(Figure7)
Placethehobinthemiddleofthehole.
Securethe unit on the counter by using the installation
sheetandscrews.(Figure7and8)
Electricconnectionshouldbeconductedbyacompetentandauthorizedperson.
Theelectriccableofyourhobshouldnotbelaidinhotplaces.
Whenthepowercableisdamaged,itshouldreplacedbytheauthorizedservicedealer.
Noreducer,adapter,andswitchshouldbeusedforelectricalconnectionsinceitwillcauseexcessive
heatandfire.
Plugtheelectriccabletoagroundedwallsocket.Themanufacturercannotbeheldresponsibleifyou
failtodoso.
Thesupplydataoftheelectricnetworkshouldbesuitablewiththedataonthetypelabeloftheunit.
These instructions are prepared for specialist personnel having required competence. Installation of the
equipmentshouldbesuitableaspertheapplicablestandards.Allgasrelatedworksshouldbeconductedwhen
theelectricconnectionwascut.Thevalueplateonthehobindicatesthegastypeintendedtobeusedforuse
withthehob.Connectiontothegassupply(mainsorgascanister)shouldbedoneafteradjustingthehobto
theintendedsupplytype.NotethattheLPGhoodsshouldhaveTSEstampand300mmSS(30mbar)outlet
pressure.Naturalgaspressureis200mmSS(20mbar).Pleaseconsulttheauthorizedserviceforconversion
tonaturalgasorLPG.Useonlypiping,gasketsorsealaspertheapplicablenationalstandards.
Insomecountrieswhereconicconnectionsareobligatory,conicconnectionisprovided.Insuchacasethe
conicconnectionpartshouldbeconnectedtotheunit.Iftheunitwillbeconnectedtoaflexiblehose,thelength
ofthehoseshallnotexceed120cm.
Beforestartingworksrelatedtogasinstallation,pleasecutthegassupply.Maketheconnectionsothatno
pressurewillbeappliedontheconnectionnutsandpiping.Makesurethatthepipewillnotcauseanyclogging
orcontactwiththesharpcorners.NotethatthegashoseshouldbeTSEcertifiedandnotbelaidthroughhot
areas.

Figure7.
InstallationClamp
Figure8.