13
Finally, the DENSITY ALTITUDE screen is calculated from the absolute values of station pressure,
relative humidity and temperature, and is not aected by the reference values entered in the BARO and
ALTITUDE screens.
MAIN SETUP MENU
You can customize your Kestrel Meter in multiple ways. Press the button to access the Main Setup Menu.
Press the button to select the highlighted setting. The Main Setup Menu contains: OFF, Memory Options,
Measurements, Graph Scale, Units, User Screens, System, Date & Time, Language and Restore.
O
Press the then the button to turn the display o. Even when the Kestrel Meter’s display is turned
o, the unit will continue to automatically store data at the dened Store Rate. The battery life will be
decreased if data is stored frequently. The only way to completely shut o the unit is to remove the
batteries. Custom settings and data will be stored when the batteries are removed.
Memory Options
These settings control the data storage properties.
Setting Description Operation
Clear Log
(Go/Done)
All stored data is cleared. This will also clear
Min/Max/Avg data.
Press or to clear the log.
Reset MMA
(Go/Done)
All Min/Max/Avg data is cleared. Chart data
will remain intact.
Press or to clear the MMA.