16
6
TEST EDGE
Safety edge test
0 = disabled
1 = active
0 0 1
7
SETUP PART
Length of the partial opening travel (PAR) expressed as a
percentage of the total travel.
NOTE: only the leaf relating to the M1 motor opens
50 0 100 %
8
CLOSE PART
Automatic re-closing time from partial opening PAR (0 = o󰀨) 0 0 900 s
9
FLASH SETUP
Determines the behaviour of the FLASH output
0 = output always active (not ashing) during the opening and
closing manoeuvre
1 = output ashing during the opening and closing
manoeuvre
1 0 1
10
PRE SETUP
Determines the pre-ashing modes of the FLASH output
(deactivated if PRE TIME = 0)
0 = pre-ashing before each opening and closing manoeuvre
1 = pre-ashing before each closing manoeuvre
2 = pre-ashing before each opening manoeuvre
0 0 2
11
PRE TIME
Determines the duration of the pre-ashing (0 = o󰀨) 0 0 20
s
12
PRE TIME
Courtesy light conguration
0 = on during the manoeuvre and, at the end of the
manoeuvre, for the
TIME time LIGHT
1= on if the gate is not closed for the
TIME time
LIGHT
with the gate closed.
2 = lit for a
TIME LIGHT
time after each command
(OPEN, CLOSE, PAR, SBS)
0 0 2
13
TIME LIGHT
Courtesy light switching on time.
NOTE: the courtesy light can also be turned on and o󰀨 by radio
remote control; if turned on by radio emote control, it can only
be turned o󰀨 by radio remote control.
0 0 900
s
14
HOLD TORUN
Enables the “man present” functionality on the SBS, PAR,
OPEN and CLOSE inputs
WARNING !
enabling the function, the operation of the
radio remote controls is inhibited
0 0 1
15
INDIC LIGHT
Determines the operation of the IND/ELEC output
0 = o󰀨
1 = gate open indicator active if the gate is not closed
2 = proportional gate open indicator
- Slow ashing during opening
- Fast ashing during closing
- Two ashes + pause if stopped and not closed
3 = electric lock
4 = magnetic lock, output active if the gate is closed.
WARNING !
interface the magnetic lock with a relay with
24VDC coil and set ELECT TIME ≠ 0.
0 0 4
16
CYCLE SERVI
Species the number of manoeuvres before reporting a
maintenance request.
NOTE: the signalling occurs using the FLASH output; if closed
it ashes continuously
10 0 200
X1000
cycles
17
SETUP SERVI
Enables maintenance request reporting
0 = disabled
1 = active
0 0 1
18
ELECT TIME
Electric lock activation time or magnetic lock deactivation time. 2 1 10 s
19
EL-OP SETUP
Water hammer on opening (0 = o󰀨).
When closed, it pushes to close before opening; it is used to
facilitate the release of the electric lock
0 0 100 100 ms
20
EL-CL SETUP
Water hammer on closing (0 = o󰀨).
At the end of the closing manoeuvre, the motor is kept active
for the set time; it is used to facilitate the coupling of the
electric lock.
0 0 100 100 ms
21
RELEA TIME
Release on opening and closing limit switches.
0 = no release
10 = maximum release
In the presence of light gates, it reduces the bending of the
leaf.
0 0 10