EN
15
8
SBS SETUP
Determines the operating mode of the step-by-step control
(SBS)
0 = normal AP-ST-CH-ST-AP-ST…
1 = alternate STOP AP-ST-CH-AP-ST-CH…
2 = alternate AP-CH-AP-CH…
3 = condominium mode 1; from an open position, the closing
manoeuvre begins when the automatic re-closing timer
expires
NOTE: closure does not take place if
AUTOCLOSE
= 0
4 = condominium mode 2; an SBS command performs
the closing manoeuvre only if the leaf is in the open
position.
0 0 4
9
DELAY LEAF2
Delay of the leaf relative to M2 during opening 2 0 300
10
LENGH SLOW
Travel width at low speed (slowing down phase) both during
opening and closing
P = customised (paragraph 4.4.2)
20 0 100 %
11
BLACK OUT
Determines the behaviour of the control panel when switched
on
0 = no action
1 = executes, if possible, the closing command
0 0 1
12
STAND BY
If active, in closed position, disables PH-POW power supply 0 0 1
13
1/2 MOTOR
Number of system doors 2 1 2
PARAMETERS DESCRIPTION DEFAULT MIN MAX UNIT
1
FOTO1 SETUP
Determines the behaviour of the automation, starting from the
closed position,
0 = if PH1 is engaged it does not execute any opening
command
1 = if PH1 is engaged it still executes the opening
command
1 0 1
2
FOTO2 SETUP
Veries the engaged status of PH2
0 = active both during the opening and closing
maneuvers
1 = only active during the opening manoeuvre
0 0 1
3
PHOTO TEST
Photocell functionality test
0 = no tests
1 = checks the functionality of the photocells connected
to terminal PH1
2 = checks the functionality of the photocells connected
to terminal PH2
3 = checks the functionality of the photocells connected
to terminals PH1 and PH2
0 0 3
4
TYPE EDGE
Determines the type of safety edge connected to the EDGE/
EDGE terminals
0 = STOP NC contact
1 = 8k2 safety edge
2 = NC sensitive edge
0 0 2
5
SETUP EDGE
Determines in which situations
the intervention of the safety edge connected to the EDGE/
EDGE inputs should be evaluated
0 = status of the EDGE/EDGE input evaluated
only during the closing manoeuvre; the intervention
involves a total opening manoeuvre
1 = intervenes both in opening and closing
stopping the automation and reversing the direction of
travel for approximately 2 seconds
2 = intervenes both in opening and closing
stopping the automation and reversing the direction of
travel for approximately 0.5 seconds
0 0 2