EasyManua.ls Logo

Key Automation CT20324 - 4.6 - Factory Parameters Reset; 5 - System Customisation; 5.1 - Basic Parameters

Key Automation CT20324
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
14
5 - SYSTEM CUSTOMISATION
4.6 - Factory parameters reset
To return all the parameters to their default values or to change the type of equipment on which the control panel is installed, proceed
as follows:
1. Press and hold the button
(MENU); the display shows in sequence
BASE ADV
; release the button near the text ADV.
2. Scroll through the menu items with the buttons
(UP) and (DOWN-RADIO) until reaching
MOTOR SETUP
3. Press and hold the button
(MENU); release the button when the display starts ashing; the number displayed indicates the type
of motor in use.
4. Select with the buttons
(UP) and (DOWN-RADIO) the type of motor; press and hold the button (MENU).
The display shows a countdown from 50 to 0; release the button when the text
DONE
appears.
5. The control unit exits the MENU after seven seconds of inactivity or by briey pressing the
(MENU) button.
WARNING !
If the type of motor is changed, all the values are returned to the factory value and it is necessary to perform a new
auto-learning procedure for the travel.
The conguration menus of the equipment operating functions are divided into BASE and ADV (basic/advanced). The following tables
show the description of each basic parameter with the respective minimum, maximum and default values.
1. Press and hold the button
(MENU); the display shows in sequence
BASE
and
ADV
, release the button at the wording
BASE
to
access the basic menu.
2. Scroll through the menu items with the buttons
(UP) and (DOWN-RADIO) until reaching the desired parameter
3. Press and hold the button
(MENU) until the display ashes; release the button (MENU)
4. To change the value, use the buttons
(UP) and (DOWN-RADIO) ; to conrm the new value press and hold the button
(MENU) until the display stops ashing
5. To exit the menu, briey press the button
(MENU)
NOTE: to view the value of any parameter simply enter the relevant menu (BASE or ADV) using steps 1 and 2 of the procedure just
described. Once the desired parameter has been identied, the display alternately shows the name of the parameter and the value.
To exit the menu, briey press the button
(MENU)
PARAMETERS DESCRIPTION DEFAULT MIN MAX UNIT
1
AUTO CLOSE
Automatic re-closing time (0 = o󰀨) 0 0 900 s
2
PHOTO CLOSE
Re-closing time after the transit on PH1 (0 = o󰀨) 0 0 30 s
3
REACT TIME
Obstacle sensitivity
0 = maximum impact force
10 = minimum impact force
3 0 10
4
OPEN SPEED
Door speed in opening
1 = minimum speed
5 = maximum speed
4 1 5
5
SL-OP SPEED
Door speed during the slowing down phase in opening
1 = minimum speed
5 = maximum speed
1 1 5
6
CLOSE SPEED
Door speed in closing
1 = minimum speed
5 = maximum speed
4 1 5
7
SL-CL SPEED
Door speed during the slowing down phase in closing
1 = minimum speed
5 = maximum speed
1 1 5
5.1 - Basic parameters