1
Accessories
• Instruction manual (x 1)
• Mounting bracket [FS-V11(P) only]
• End unit (x 2) [FS-V12(P) only]
• Directions (x 1) [FS-V12(P) only]
SAFETY PRECAUTIONS
• This product is just intended to detect the object(s). Do not use
this product for the purpose to protect a human body or a part
of human body.
• This product is not intended for use as explosion-proof
product. Do not use this product in a hazardous location and/or
potentially explosive atmosphere.
SPECIFICATIONS
1. The response time varies depending on the number of expansion units connected.
2. The orange LED is normally part of the bar graph LED monitor. It is used as a calibration
indicator during the setting of the sensitivity.
3. When several units are connected, the allowable ambient temperature changes depending
on the following conditions. To connect several units, be sure to mount them to a DIN rail
(metal DIN rail). Make sure that the output current is 20 mA. max.
• When 3 to 10 units are connected: -10 to +50 °C (14 to 122°F)
• When 11 to 16 units are connected: -10 to +45 °C (14 to 113°F)
Model NPN output FS-V11 FS-V12 FS-V10
PNP output FS-V11P FS-V12P —
Light source Red LED
Response time 250 µs (FINE)/500 µs (TURBO)/ 410 µs to 1.7 ms
1.
1 ms (SUPER)
Operation mode LIGHT-ON/DARK-ON (switch selectable)
Indicators Output indicator: Red LED
Digital LED monitor: Red LED
Bar graph LED monitor: Green/Orange LED
2.
Calibration indicator: Orange LED
2.
Timer function OFF-delay: 40 ms, 10 ms
Timer OFF
Control output NPN or PNP open-collector 24V 100mA max.
Residual voltage: 1V max.
Protection circuit Reverse polarity protection, Over-current protection,
Surge absorber
Power supply voltage 12 to 24 VDC ±10%, Ripple (P-P) 10% max, Class 2
Current consumption 50 mA max.
Ambient illumination Candescent lamp: 10,000 lx max., Sunlight: 20,000 lx max
Ambient temperature
3.
-10 to +55°C (14 to 131°F), No freezing.
Relative humidity 35 to 85%, No condensation
Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y and
Z directions for two hours
Shock immunity 500 m/s
2
in X, Y and Z directions, three times each
Housing material Body/Cover: Polycarbonate
Weight Approx. 80 g Approx. 45 g Approx. 20 g
(including 2-m cable)
SELECTING DISPLAYED DATA
■ Displaying received light intensity
Received light intensity is displayed approximately 4000 is the
maximum setting.
Note: The MAX and MIN values vary depending on the fiber unit
connected.
■ Displaying excess gain
Received light intensity is converted by defining the setting value as
100 P (%).
■ Displaying the hold value
The peak value or the minimum value of the received light intensity or
excess gain is displayed.
The setting of the output selector switch determines whether the peak
value or the minimum value is displayed.
PART NAMES AND FUNCTIONS
FS-V11(P)
(Main unit)
SUPER
D. ON
MODESET
L. ON
TURBO
FINE
SET
40ms
OFF
10ms
SET
MODE
SUPER
D. ON
MODESET
L. ON
TURBO
FINE
SET
40ms
OFF
10ms
Operation indicator
(Red)
Bar graph LED
monitor
Calibration indicator
(Orange)
Digital LED monitor
Auto SET
button
Manual
button
MODE
button
Output
selector switch
DARK-ON
LIGHT-ON
3-core
cable
FS-V12(P)
(Expansion unit)
Expansion
connector
Single-core
cable
Output selector switch Display Hold value
LIGHT-ON Peak-hold value
DARK-ON Bottom-hold value
Displaying the setting value
Press
or once while the received light intensity is displayed.
The setting value flashes for 2 seconds, and then the received light
intensity appears once more.
Note: To change the setting value, press or while the setting
value is flashing.
Press this
button once.
Received light intensity
Hold display
(Light intensity)
Press this
button once.
Display
changes
alternately.
Display
changes
alternately.
Press this
button once.
Press this
button once.
Hold display
(Excess gain)
The display changes every time the MODE button is pressed.
Excess gain display (%)
SUPER
D. ON
MODESET
L. ON
TURBO
FINE
SET
40ms
OFF
10ms
Expansion
connector
FS-V10
(Expansion unit)
PRECAUTIONS ON REGULATIONS AND STANDARDS
■ UL Certificate
This product is an UL/C-UL Listed product.
• UL File No. E301717
• Category NRKH,NRKH7
• Enclosure Type 1 (Based on UL50)
Be sure to consider the following specifications when using this
product as an UL/C-UL Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC:
National Electrical Code).
• Power supply/ Control input/ Control output circuits shall be
connected to a single Class 2 source only.
• Use with the over current protection device which is rated 24V or
more and not more than 2A.
Hybrid Fiberoptic Sensors
FS-V11(P)/12(P)/10
Instruction Manual
96M11225
Read this manual before using the product in order to achieve
maximum performance.
Keep this manual in a safe place after reading it so that it can be used
at any time.