Technical Guide
Installing and Connecting System Components

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Keyscan CA8500 Series and is the answer not in the manual?

Summary

Installation Requirements

Power

Specifies transformer requirements (voltage, VA) for ACU power and warnings.

Electrical Precautions

Safety instructions for electrical work, including power off and grounding.

Cables

Grounding

General Installation Guidelines

Mounting Access Control Units and Components

Guidance on convenient and suitable location for ACUs and power supplies, avoiding high-voltage equipment.

Mounting Readers and Door Hardware

Positioning readers and door hardware, ensuring proper operation before connection.

Terminate Wiring at the ACU

Communication

Establishing communication between PCs with software and access control units.

Power Up and Test Voltages

Procedures for powering up the system and verifying correct voltages for proper function.

Terminate Lock Wiring

Guidance on wiring door strikes and magnetic locks, including power supply considerations.

Fail Safe;Fail Secure Lock Devices

Instructions for connecting fail-safe and fail-secure door strikes to relay outputs.

Mounting - Enclosure & Components

Mounting the Metal Enclosure

Instructions for mounting the metal enclosure to a wall, considering location and distances.

Mounting the PC109 x Control Board to Metal Standoffs

Procedures for securing the control board to metal standoffs inside the enclosure.

Grounding Communication Cable Shield

Mounting - Readers & Door Hardware

Door Lock Hardware

Guidance on selecting and installing door lock hardware, adhering to codes.

Readers

Terminate Input Wiring

Terminate Reader Wiring at ACU

Reader Wiring

Outlines the wiring color codes and connection points for proximity readers.

Jumper Settings

System Configuration - Jumper J16

Details on J16 jumper settings for baud rate and communication terminal activation.

Reader Configuration - Jumper J3

Describes J3 jumper settings for accommodating different reader formats and security levels.

Power-up & Test Voltages

Power Supply Specifications

Details on the DPS-15 power supply's dual outputs and current ratings.

Wiring Connections

Essential points to check before connecting power, ensuring safety and correct connections.

DPS-15 Dual Power Supply - Current Calculation

Using tables to calculate total current demand from ACU and RDR AUX supplies.

System Power-up

Control Board Voltage Test Points

Test Points - Communication Terminals

Communication Diagnostics

Communication Status LEDs

Outlines the meaning of communication LEDs on CA, EC, CB-485, and CPB-10-2 boards.

System Status LED

Appendix I - Reverse Network

Set IP Address on Access Control Boards

Procedure to set IP addresses for reverse network communication via Hyper Terminal.

Current Ratings

Relay States

Summary

Installation Requirements

Power

Specifies transformer requirements (voltage, VA) for ACU power and warnings.

Electrical Precautions

Safety instructions for electrical work, including power off and grounding.

Cables

Grounding

General Installation Guidelines

Mounting Access Control Units and Components

Guidance on convenient and suitable location for ACUs and power supplies, avoiding high-voltage equipment.

Mounting Readers and Door Hardware

Positioning readers and door hardware, ensuring proper operation before connection.

Terminate Wiring at the ACU

Communication

Establishing communication between PCs with software and access control units.

Power Up and Test Voltages

Procedures for powering up the system and verifying correct voltages for proper function.

Terminate Lock Wiring

Guidance on wiring door strikes and magnetic locks, including power supply considerations.

Fail Safe;Fail Secure Lock Devices

Instructions for connecting fail-safe and fail-secure door strikes to relay outputs.

Mounting - Enclosure & Components

Mounting the Metal Enclosure

Instructions for mounting the metal enclosure to a wall, considering location and distances.

Mounting the PC109 x Control Board to Metal Standoffs

Procedures for securing the control board to metal standoffs inside the enclosure.

Grounding Communication Cable Shield

Mounting - Readers & Door Hardware

Door Lock Hardware

Guidance on selecting and installing door lock hardware, adhering to codes.

Readers

Terminate Input Wiring

Terminate Reader Wiring at ACU

Reader Wiring

Outlines the wiring color codes and connection points for proximity readers.

Jumper Settings

System Configuration - Jumper J16

Details on J16 jumper settings for baud rate and communication terminal activation.

Reader Configuration - Jumper J3

Describes J3 jumper settings for accommodating different reader formats and security levels.

Power-up & Test Voltages

Power Supply Specifications

Details on the DPS-15 power supply's dual outputs and current ratings.

Wiring Connections

Essential points to check before connecting power, ensuring safety and correct connections.

DPS-15 Dual Power Supply - Current Calculation

Using tables to calculate total current demand from ACU and RDR AUX supplies.

System Power-up

Control Board Voltage Test Points

Test Points - Communication Terminals

Communication Diagnostics

Communication Status LEDs

Outlines the meaning of communication LEDs on CA, EC, CB-485, and CPB-10-2 boards.

System Status LED

Appendix I - Reverse Network

Set IP Address on Access Control Boards

Procedure to set IP addresses for reverse network communication via Hyper Terminal.

Current Ratings

Relay States

Keyscan CA8500 Series Specifications

General IconGeneral
BrandKeyscan
ModelCA8500 Series
CategoryControl Unit
LanguageEnglish