Keysight InfiniiVision
2000 X-Series Oscilloscopes
User's Guide

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies DSO-X 2014A and is the answer not in the manual?

Keysight Technologies DSO-X 2014A Specifications

General IconGeneral
Bandwidth100 MHz
Vertical Resolution8 bits
Input CouplingAC, DC, GND
Timebase Range5 ns/div to 50 s/div
Sample Rate1 GSa/s
Display8.5 inch WVGA LCD
Input Impedance1 MΩ
ConnectivityUSB, LAN
Waveform Update Rate100, 000 wfms/s
Trigger TypesEdge, Pulse, Video
Operating Temperature0 °C to 50 °C

Summary

Getting Started

Connect Probes to the Oscilloscope

Guides on connecting oscilloscope probes to channels and ground points.

Compensate Passive Probes

Explains the process of compensating passive probes for accurate measurements.

Horizontal Controls

To adjust the horizontal (time/div) scale

Adjusts the horizontal scale (sweep speed) to change the time/div setting.

Vertical Controls

To adjust the vertical scale

Adjusts the vertical scale (volts/division) for analog channels.

Math Waveforms

Digital Channels

To connect the digital probes to the device under test

Details connecting digital probes to the MSO oscilloscope and device.

Serial Decode

Display Settings

Triggers

Edge Trigger

Explains how to set up triggers based on waveform edge slope and voltage.

Pattern Trigger

Describes triggering based on a specific pattern of channel states.

Trigger Mode/Coupling

To select the Auto or Normal trigger mode

Explains how to choose between Auto and Normal trigger modes.

To select the trigger coupling

Sets trigger path coupling (DC, AC, LF Reject, TV).

Acquisition Control

Running, Stopping, and Making Single Acquisitions (Run Control)

Details how to start, stop, and capture single acquisitions.

Selecting the Acquisition Mode

Explains different acquisition modes like Normal, Peak Detect, Averaging.

Cursors

To make cursor measurements

Guides on using cursors for custom voltage, time, and phase measurements.

Measurements

To make automatic measurements

Instructions for performing automatic measurements on waveforms.

Mask Testing

To create a mask from a "golden" waveform (Automask)

Guides on automatically creating a mask from a reference waveform.

Waveform Generator

Save/Recall (Setups, Screens, Data)

Saving Setups, Screen Images, or Data

Instructions for saving oscilloscope setups, screen images, and data.

Recalling Setups, Masks, or Reference Waveforms

Guides on recalling saved setups, masks, and reference waveforms.

Utility Settings

Setting up the Oscilloscope's LAN Connection

Guides on setting up the LAN connection for network access and remote control.

Web Interface