15 | Keysight | FieldFox Handheld Analyzers - Configuration Guide
FieldFox SA upgrades
N9935AU, N9936AU, N9937AU, N9938AU,
N9960AU, N9961AU, N9962AU
Option Description Upgrade contents Additional requirements
030 Remote control capability License key None
100 3.5 mm connectors Not applicable Not applicable
208 USB power sensor measurements versus frequency License key 302
209 Extended range transmission analysis (ERTA) License key
220
1
220 Full-band tracking generator License key None
235 Preamplifier function License key None
236 Interference analyzer and spectrogram License key None
238 Spectrum analyzer time gating License key None
302 External USB power sensor support License key None
307 GPS receiver License key None
309 DC bias variable-voltage License key None
310 Built-in power meter License key None
312 Channel scanner License key None
320 Reflection measurements License key
2
– Option 220 for all models
– Option 100 and 220 for N9938A
330 Pulse measurements License key None
350 Real-time spectrum analyzer (RTSA) License key
3
None
351 I/Q Analyzer (IQA) License key
3
None
355 Analog demodulation License key None
1. 209 is a system based on two FieldFoxes. See page 6, FAQ #10, for a detailed description of the system requirements.
2. On N9938A, Option 320 is only available as a software upgrade if the spectrum analyzer is already equipped with Option 100, which is 3.5 mm connectors
on the test port. Option 100 must have been ordered at the time of original purchase. It cannot be upgraded later.
3. Requires CPU2 fast processor. See page 6, FAQ #13.
Upgrades (continued)
Information on upgrades is available from: www.keysight.com/find/fieldfoxsupport
FieldFox RF and microwave analyzers hardware upgrades
Model Number/
Option
1,2
Description Upgrade contents Additional requirements
N9910HU-100 N9913/14/15/16/17A processor upgrade Improved performance for
N9915/16/17A models
Return to service center only
N9910HU-200 N9925/26/27A processor upgrade Improved performance for
N9925/26/27A models
Return to service center only
N9910HU-300 N9935/36/37A processor upgrade Improved performance for
N9935/36/37A models
Return to service center only
N9910HU-400 N9918/28/38A processor upgrade Improved performance for
N9918/28/38A models
Return to service center only
1. Upgrades are not available for FieldFox analyzers with serial number prefix starting with MY5607/SG5607/US5607, as these analyzers already have the
improved hardware.
2. Please contact your local Keysight Service Center for instructions on how and where to send the instrument, and how to order the factory upgrades.

Other manuals for Keysight Technologies FieldFox N9938A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies FieldFox N9938A and is the answer not in the manual?

Keysight Technologies FieldFox N9938A Specifications

General IconGeneral
BrandKeysight Technologies
ModelFieldFox N9938A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals