Dynamic Range | > 100 dB (typical) |
---|---|
Instantaneous Bandwidth | 10 MHz |
Cable and Antenna Analyzer | Yes |
Vector Voltmeter | Yes |
Spectrum Analyzer | Yes |
Tracking Generator | Yes |
Measurement Types | Cable and antenna analysis |
DANL (Displayed Average Noise Level) | -155 dBm/Hz |
Amplitude Accuracy | +/- 0.5 dB |
Power Meter | Yes |
Input Impedance | 50 Ohm |
Operating Temperature | -10 °C to +50 °C |
Interface Ports | USB, LAN |
Battery Life | Up to 4 hours (typical use) |
Dimensions (H x W x D) | 8.3 x 10.5 x 3.1 inches |
Describes CAUTION and WARNING symbols used in the manual.
Lists safety points for servicing the network analyzer.
Discusses ESD protection recommendations and requirements.
Defines instrument markings and battery disposal instructions.
Lists the documentation available for the FieldFox analyzer.
Provides cleaning instructions for external surfaces and information about electrical maintenance.
Lists the available FieldFox analyzer models.
Lists the options available for the FieldFox analyzer.
Provides internet addresses for assistance, service options, and shipping information.
Items to consider or procedures before testing, including environment, ESD, and connector care.
Lists recommended additional test equipment for servicing the FieldFox analyzer.
Procedures to perform before returning a serviced instrument to the customer.
An operation check to be performed before returning an instrument to a customer.
Lists performance tests included in the Keysight N7841A software package.
Lists adjustments included in the Keysight N7841A software package.
Information pertaining to ESD protection.
Information about monitoring internal temperatures and temperature control modes.
A starting point to begin troubleshooting.
Troubleshooting power-up problems.
Problems with the front panel assemblies of the analyzer.
Problems with the measurement group assemblies of the analyzer.
Summarizes the theory of operation for the analyzer and its major functional groups.
Describes the operation of assemblies associated with the front panel group.
Describes the operation of assemblies associated with the measurement group.
Describes different operating modes and the hardware used in each.
Information about temperature sensors and analyzer response to temperature data.
Descriptions of one-port and two-port calibrations for CAT and NA modes.
Information about firmware and firmware upgrades.
How to order a replaceable part from Keysight Technologies.
The correct sequence for determining failure and replacing a defective assembly.
Tables with illustrations listing all replaceable parts in the analyzer.
Lists replaceable parts for the front panel assembly.
Lists replaceable parts for the measurement group assembly.
Lists replaceable parts for the case group.
Lists miscellaneous parts and accessories not illustrated in the main groups.
Warnings and cautions pertaining to personal safety during service.
Information pertaining to ESD protection during service.
Step-by-step procedure to identify, replace, and re-adjust faulty assemblies.
A table listing removal and replacement procedures and their page numbers.
Tests, verifications, and adjustments to perform on the analyzer after repair.
Procedures for removing and replacing the processor for upgrade kits.
How to view options, firmware revision, error log, temperature, and erase user data.
How to view installed options and re-install options after repair.
How to check current firmware revision and find info on firmware upgrades.
Information about cleaning the display and battery maintenance.