Page 29Find us at www.keysight.com
85133F
1
set, flexible:
One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
p/n 85133-60016
One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
p/n 85133-60017
85133H
1
Single, flexible: 2.4 mm (f) to 2.4 mm (m),
63 cm, 25 inches
N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapter set
85130E 2.4 mm
1
to 7 mm
85130F 2.4 mm
1
to 3.5 mm
85130G 2.4 mm
1
to 2.4 mm
For devices with K connectors (2.92 mm)
Mechanical calibration kits
85056KE01 DC to 40 GHz
For use with user supplied 2.9 mm test port cables.
2.92 mm (K connector) calibration kit with fixed and sliding
loads. The Keysight 85056KE01 calibration kit is an ordering
convenience to allow the pass through ordering from
Keysight for the Maury 8770C47 calibration kit.
85056KE02 DC to 40 GHz
For use with user supplied 2.92 mm test ports cables.
2.92 mm (K connector) calibration kit with fixed loads only.
The Keysight 85056KE02 calibration kit is an ordering
convenience to allow the pass through ordering from
Keysight for the Maury 8770D47 calibration kit.
The 85056KE01 and 85056KE02 contains one NMD
2.4 mm
2
(f) to 2.92 mm (f) and one NMD 2.4 mm
2
(f) to
2.92 mm (m) test port adapter to adapt the 2.4 mm test
ports of the PNA to 2.92 mm. It also supplies 2.92 mm to
2.92 mm in-series adapters (3 adapters) and a PNA Cal
Coefficients on a USB stick. Users must supply their own
2.92 mm or K-connector test port cables. Also included is a
2.92 mm torque wrench.
Maury Microwave Terms and Conditions for Warranty and
Return apply. Maury Microwave Corp. calibration kits are to
be returned directly to Maury Microwave for service, repair,
or calibration issues and not to Keysight Technologies. For
additional information go to www.maurymicrowave.com.
Keysight Technologies does not guarantee the performance
of the Maury calibration kits or the system performance
when connected to Keysight Microwave PNA Series network
analyzers.
For devices with 2.4 mm connectors
Mechanical calibration kit
85056A standard: DC to 50 GHz. Includes:
00901-60003 2.4 mm (m) fixed broadband load
00902-60004 2.4 mm (f) fixed broadband load
00915-60003 2.4 mm (m) sliding load
00915-60004 2.4 mm (f) sliding load
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
85056-60020 2.4 mm (m) short
85056-60021 2.4 mm (f) short
85056-60022 2.4 mm (m) open
85056-60023 2.4 mm (f) open
85056D economy: DC to 50 GHz. Includes:
00901-60003 2.4 mm (m) fixed broadband load
00902-60004 2.4 mm (f) fixed broadband load
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
85056-60020 2.4 mm (m) short
85056-60021 2.4 mm (f) short
85056-60022 2.4 mm (m) open
85056-60023 2.4 mm (f) open
Electronic calibration kits
N4693A Microwave ECal: 10 MHz to 50 GHz, 2-ports.
Includes:
Option M0F module with:
N4693-60001 2.4 mm (f) to 2.4 mm (m) ECal module
Option 00M module with:
N4693-60002 2.4 mm (m) to 2.4 mm (m) ECal module
Option 00F module with:
N4693-60003 2.4 mm (f) to 2.4 mm (f) ECal module
Option 00A adds:
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
Cables
Note: Keysight offers the following 2.4 mm test port cables.
Adapters will be necessary when using these cables for 2.92 mm
measurements.
85133C
1
single, semi-rigid:
2.4 mm (f) to PSC-2.4 mm (f), 81 cm, 32 inches
85133D
1
set, semi-rigid:
One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
p/n 85133-60001
One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
p/n 85133-60002
85133E
1
single, flexible:
2.4 mm (f) to PSC-2.4 mm (f), 97 cm, 38 inches
1. Special rugged female connector specifically for connecting to the network analyzer test port, but does not mate with a standard male connector.
2. Special rugged female connector specifically for connecting to the network analyzer test port, but does not mate with standard 2.4 mm male connector

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N5249A and is the answer not in the manual?

Keysight Technologies N5249A Specifications

General IconGeneral
BrandKeysight Technologies
ModelN5249A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals