30 Keysight X-Series Signal Generators Error Messages
Error Messages
List of Error Messages
is not found the operations cannot be executed. Digital
personalities are also considered subsystems.
-280 Program error; The following error is not recognized:{name}
The specified error is not recognized by the system. Report this
error to service office.
-280 Program error; The following SCPI command generated an error:{name}
The SCPI command generated an error.
-278 Macro header not found
A syntactically legal macro label in the *GMC? query could
not be executed because the header was not previously defined.
-277 Macro redefinition not allowed
The macro label defined in the *DMC command could not be
executed because the macro label was already
defined (see IEEE 488.2, 10.7.6.4).
-276 Macro recursion error
A syntactically legal macro program data sequence could not
be executed because the device found it to be
recursive (see IEEE 488.2, 10.7.6.4).
-275 Macro definition too long
A syntactically legal macro program data sequence could not