Keysight X-Series Signal Generators Error Messages 89
Error Messages
List of Error Messages
and reported an arming timeout. There is no automatic
re-synchronization. The feature is only available when Real-Time
Custom is on and the BBG data clock is set to External.
-221 Settings conflict; RPICH is only defined for Radio Configuration 3 and
4. You must set one of these Radio Configurations before configuring
or using this code channel.
An attempt was made to setup the R-PICH while in a radio
configuration that does not support this channel. This channel is
only available in RC3 and RC4. If the R-PICH is the desired
channel, you must change to the proper radio configuration before
continuing.
-221 Settings conflict; RSCH is only defined for Radio Configuration 1 and
2. You must set one of these Radio Configurations before configuring
or using this code channel.
The command attempted to enter a value or setting for the R-SCH in
RC1 or RC2. If this is the correct R-SCH, change to the desired
radio configuration and resend the command. If not, select the
command for the desired R-SCH. Use the following list to determine
the correct R-SCH command to use: R-SCH: Used in RC1 and RC2
R-SCH1: Used in RC3 and RC4 for Channel 4 R-SCH2: Used in RC3 and
RC4 for Channel 2
-221 Settings conflict; RSCH with Turbo coding is only available in Radio
Configurations 3 and 4. You must set one of these Radio Configurations
to proceed
Turbo coding is only allowed in R-SCH in RC3 and RC4. If turbo