4. Introduction, Product Features and Specifications
Introduction
This alarm detects carbon monoxide using an electrochemical cell. Many times throughout this User Guide,
we will refer to Carbon Monoxide as “CO.”
Ten (10) years after the unit was installed, this unit will automatically alert you that it is time to replace the unit.
This is called “End of Unit Life” mode. See Troubleshooting Guide. To help track the life of your alarm, write the
installation date in the space provided on t
he side of the alarm. A label has been provided that has important
information on what to do in case of a CO alarm. Place the label at eye level on a wall near the alarm after it is
mounted.
Product Features and Specifications:
Temperature Operating Range: -10°C to 45°C
Humidity Operating Range: up to 90% RH non-condensing
Audible Alarm: 85+ dB(A) at 3 m, 3.0 to 3.5 kHz pulsing alarm
Digital Display (K5DCO only)
NOTE: Depending on the ambient condition (temperature, humidity) and the condition of the sensor,
the display readings may vary. The digital readings tolerances are 0-999 ± 30% +15ppm during these
conditions: Ambient: 27°C ± 12°C (80°F ± 10°F), atmospheric pressure ±10%, 40% ± 3% relative humidity
CO Sensor: Electrochemical
Peak Level Memory (K5DCO only)
CO Alarm Reset
Powered by AA batteries
Storage and Transport Conditions: -20° C to +60° C, 5-95%RH (non-condensing)