When you first power up the alarm: The red Alarm LED will light and
the alarm will chirp once.
CO alarm power indicators:
AC - Digital display constantly on.
DC Only - Green LED flashes briefly once every 60 seconds.
Within a few minutes, your carbon monoxide alarm will start monitoring
for CO and will continue to do so as long as it receives power.
Whenever the KN-COP-DP-10YHCA is operating, the digital display will display
“0” (with AC applied) to indicate the unit is monitoring for CO. If the alarm
senses dangerous levels of CO, the digital display will alternate between “CO”
and the measured CO concentration in parts per million (PPM), and the alarm
will emit an audible alarm pattern, and the Escape light will illuminate.
How to Install Your Alarm
To install:
1. Remove the switch cover.
2. Choose a standard 120V unswitched outlet
to plug the alarm into.
3. If outlet is mounted sideways (horizontally),
rotate the plug and plug the alarm in.
Note: This model is equipped with a feature that automatically activates the
battery backup when the alarm is plugged into an AC outlet for the first time.
!
CAUTION: Do not rotate the alarm while it is plugged into an outlet, as
damage to plug may result.
4. Installation Instructions
5. Alarm Characteristics
Carbon Monoxide Alarm Indicator
When the alarm senses a dangerous level of CO, the unit will emit a loud
alarm pattern. The alarm pattern is 4 quick beeps followed by 5 seconds of
silence. This cycle repeats as long as a dangerous CO conditions exist. The
red Alarm LED will flash the same pattern, the Escape light will illuminate,
and the PPM will be displayed on the digital display.
The digital display will be brightly lit if the unit is in alarm.
WARNING: If at any time you test the alarm and it does not perform as
described, have it replaced immediately.
6. Operating Characteristics
90º ROTATING
DIRECT PLUG