WhentheVRDisclosed,anychangesthat
havebeenmadeandsavedinpedals.txt
becomeacve.
ClosingProgrammingMode
Whenyouhavefinishedviewingoreding
pedals.txt,besuretosavethefiletothe
Acvefolderifyoumadechanges.Close
theVRDbymoving
theslideswitchbackto
“Play.”
NOTE: DO NOT PRESS ANY PEDALS WHILE
WAITING FOR VRD TO CLOSE. IF YOU DO SO
AND THE DEVICE STOPS WORKING, JUST
UNPLUG IT, WAIT 15 SECONDS , THEN RE‐
CONNECT THE DEVICE.
AlternateProgrammingModeAcvaon
Ifyouhaveawaterproofmodelorprefer
nottousetheslideswitch,youcanacvate
ProgrammingModebyholdingdownany
pedalbrieflywhilepluggingtheunitinto
theUSBport.
Oryoucanholdapedal
brieflywhilestarngorre‐boongyour
computer.
ToclosetheVRDaersavinganychanges
inpedals.txt,simplyunplugandreplug
yourdevice.
Programmingbyedingpedals.txt
AtthispointyoushouldbeusingthePro‐
grammingGuide
foundonthevirtualre‐
movabledrive,ordownloadedfromthe
Kinesiswebsite(seelinkpage8).However,
abriefoverviewoftheprogrammingpro‐
cessisprovidedhere.
Usingalmostanywordprocessing(text
eding)program,youcaneditoneormore
oftheinputsavailableonvarious
Savant
Elite2products.Eachpedalorjackcan
produceoneormorekeyboardormouse
aconorcombinaonsofacons.Ped‐
als.txtcontainsbasicinstrucons,butmore
details(aswellasexampleswhichcanbe
copiedandpastedintopedals.txt)arein‐
cludedintheProgrammingGuide.Save
pedals.txtas“plaintext”or“simpletext”
whenyouaredoneeding.
(seeProgrammingGuideprovidedonthe
virtualremovabledriveofthedevicefor
details).
9
Healthandsafetyps
NewUsers,haverealiscexpectaons!
Ifyoucurrentlyhaveaninjurytoyour
handsorarms,orhavehadsuchaninjury
inthepast,itisimportantthatyouhave
realiscexpectaonsofyourinputdevice.
Youshouldnotexpectanimmediateim‐
provementinyour
physicalcondionsimp‐
lybecauseyouareusinganewinputde‐
vice.Yourphysicaltraumahasbuiltupover
monthsoryears,anditmaytakeanumber
ofweeksbeforeyounoceadifference.At
first,youmayfeelsomenewfagueor
discomfort
asyouadapttoyourKinesis
footpedal.
Footpedalisnotamedicaltreatment!
TheKinesisSavantElite2footpedalisnota
medicaltreatmentorasubstuteforap‐
propriatemedicaltreatment.Ifanyinfor‐
maoninthisguideseemstocontradict
theadviceyouhave
receivedfromahealth
careprofessional,pleasefollowyourhealth
careprofessional’sinstrucons.
Adjusngpedalforce
Ontheundersideofthepedalisasmall
plascscrewwhichmaybegently turned
toadjustpedalforceintherangeofap‐
proximately3.5to4.5lbs.Pedalsarenor‐
mallyfactoryconfiguredforlowforce.
Moldedmarksonthecartridgeindicate"+"
forhigherforce
and"‐"forlowerforce.
Usingacoin(pennyordime)orsloed
screwdriver,turn
thescrewgently to
changetheforce.
Importantnote:
Minimal force (full "‐
" adjustment) reach‐
es a hard stop. If
force is used once
the stop is felt, the
plasc screw head
may crack and pre‐
vent further force adjustments. The full
range to achieve maximum force is approxi‐
mately 10 full turns. When maximum force
(full “+” adjustment) is reached, you will
hear a "click" with each rotaon. Do not
turn further aer hearing the first click.
Fig 1. Underside of pedal