Safety devices
Pressure switch: monitors
depression in the smoke
duct. It is designed to shut
down the pellet feed screw
in the event of an obstructed
ue or signi cant back-
pressure in the presence
of wind. At the time of the
pressure switch will show
ALAR-DEP-FAIL
ALAR-DEP-FAIL
.
Pellets temperature safety:
In the rare event there is a too
high temperature in the tank,
the thermostat for pellets
safety with manual reset
creates an alarm “
ALAR-
ALAR-
SIC-FAIL
SIC-FAIL stopping the
pellet boiler stove. You need
to reset the system working
on the device placed on the
back of the thermostove.
Room thermostat: the
room thermostat detects the
present temperature in the
room. When it detects the set
temperature on the display,
the stove will go into operation
in ECO ie hold function to save
fuel. The room thermostat
should be spread so as not
to be conditioned by the
temperature of the body stove.
RESTART
PELLET
Reduction motor: if the
motor stops, the thermostove
continues to function until
the  ame goes out for lack of
fuel, and until It has cooled
down to the minimum level.
Flue gas temperature
sensor: thermocouple that
measures the temperature
of the fumes while keeping
the operation or shuts the
thermostove when the  ue
gas temperature drops below
the preset value.
Electrical safety: the
stove is protected against
violent surges of current (ex.
lightnings) by the main fuse
4 A which is located on the
control panel at the rear of
the thermostove. Other fuses
to protect the electronic
boards are to be found on
the boards themselves.
Tampering with the safety devices is prohibited. It is only after eliminating the cau-
se which gave rise to the intervention of the safety system, that it is possible to relight
the stove and thus reset the automatic operation of the sensor. To understand which
anomaly has occurred, consult this manual at paragraph relating to alarms which ex-
plains what to do based on the alarm message the stove display.