10
3). Installation Angles of the unit
Ensure the following items if there is angle on top van:
(i) The unit is backboards incline instead of forwards incline.
(ii) The inclined angle will no be larger than 7º.
If the unit is forwards inclining, the discharge of the condensation will be
affected.
The working angle of the unit will affect the lubricant of the compressor.
Ensure the body leveling.
4). Installation procedures
NoteCross the top van with crawl plate avoiding the damages on the
protecting walls of top van.
Must drill one hole through the top van:352×352mm.
The holes are in the middle of the top van, supporting the unit.
Preventing the hot air mixed into air return
5). The unit cable connection
1). Install the power supply of the unit on the right hands 352*352mm);
2). Comply with local electric standards.
3). Cable: RV 2.5mm
2
*3
4). Make the cables go through the right side of the box and leave the length
400 mm.

Related product manuals