KPM I/KPM II
ELECTRONIC SEED
MONITOR INSTRUCTION
IS364 Rev. 3/99
Throughout these instructions the symbol and the words NOTE, CAUTION, WARNING and DANGER are
used to call your attention to important safety information. The definition of each of these terms used follows:
NOTE: Indicates a special point of information.
CAUTION: Indicates that a failure to observe can cause damage to the machine or equipment.
WARNING: Indicates that a failure to observe can cause damage to the machine or equipment and/
or personal injury.
DANGER: Indicates that a failure to observe can cause most serious damage to the machine or
equipment and/or most serious personal injury.
Before beginning installation, read completely through these instructions.
Using the shipping order and/or the Contents Listings Section at the end of this instruction, check to be sure you have
all the packages needed to complete assembly.
The information used in these instructions was current at the time of printing. However, due to KINZE's continual attempt
to improve its product, production changes may cause your planter to appear slightly different in detail. KINZE
Manufacturing, Inc. reserves the right to change specifications or design without notice and without incurring obligation
to install the same on planter previously manufactured.
Right hand and left hand as used throughout these instructions is determined by facing in the direction the machine
will travel when in use, unless otherwise stated.
DANGER: Always install all safety lockups or lower planter to the ground before working around or
under the unit.
Monitor Serial Number __________________________________________________________
Measured Pulses Per Mile/KM (Radar Distance Sensor)_______________________________
Measured Pulses Per Mile/KM (Magnetic Distance Sensor) ____________________________
1 Rev. 5/98

Questions and Answers

  • P
    Paul BrownAug 12, 2025
    What to do if sensor communication alarms come on for all sensors on Kinze KPM I Measuring Instruments?
    • M
      michael26Aug 12, 2025
      If sensor communication alarms appear for all sensors on your Kinze Measuring Instruments (no bar graphs, blinking row numbers), the issue might stem from a faulty monitor, a break in the harness just after the monitor, or a dirty/corroded connector. Try replacing the monitor, inspecting and repairing the harness, or cleaning the connector.
  • D
    daviskimberlyAug 15, 2025
    Why are there bad monitor values being displayed on my Kinze KPM I Measuring Instruments?
    • A
      allison49Aug 15, 2025
      If you are experiencing bad monitor values (like speed, area, etc.) on your Kinze KPM II Measuring Instruments, it could be due to incorrect monitor settings, a faulty radar/magnetic distance sensor, or an improperly mounted radar sensor. Try changing the settings to properly correspond to the system, replacing the sensor, or properly mounting the sensor.
  • R
    Rhonda LeonardAug 20, 2025
    Why are there erroneous MPH readings at idle on Kinze Measuring Instruments?
    • D
      David JohnsonAug 20, 2025
      If you're getting erroneous MPH readings at idle with your Kinze Radar Distance Sensor, the radar gun might not be in a stable location. Relocate it to a more stable spot.
  • K
    Kyle BradshawAug 25, 2025
    How to fix single sensor communication alarm on Kinze KPM I?
    • O
      opowersAug 25, 2025
      If a single sensor communication alarm is triggered on your Kinze Measuring Instruments (alarm on, no bar graph, blinking row number), it could be due to a bad seed tube sensor, a break in the harness just before the seed tube sensor, or a dirty/corroded connector. Consider replacing the sensor, inspecting and repairing the harness, or cleaning the connector.
  • H
    hilljeremyAug 27, 2025
    What to do if sensor communication alarms come on for some sensors on Kinze KPM I?
    • J
      Javier DyerAug 27, 2025
      If sensor communication alarms appear for some sensors on your Kinze Measuring Instruments (alarm on, no bar graphs, blinking row numbers), the issue might be a break in the harness or a dirty or corroded connector. Inspect the harness and repair it. If the break cannot be found, replace the harness section corresponding with the alarming sensors. Alternatively, try cleaning the connector.
  • C
    Cassandra IngramAug 31, 2025
    What to do if underplanting alarm on a single sensor when planting on Kinze Measuring Instruments?
    • A
      Alexis BeasleyAug 31, 2025
      If you're seeing an underplanting or no planting alarm on a single sensor of your Kinze Measuring Instruments while planting (alarm on, single bar graph segment, blinking row number), it's possible the seed tube sensor is blocked or faulty. Try cleaning or replacing the sensor.
  • D
    Dr. Elizabeth JonesSep 3, 2025
    Why won't the LED light on the seed tube sensor come on Kinze KPM I?
    • B
      Beth GarciaSep 3, 2025
      If the LED light on the seed tube sensor of your Kinze Measuring Instruments won't turn on, it could be a faulty seed tube sensor, a dirty or corroded connector, or a break in the harness just before the sensor. Try replacing the sensor, cleaning the connector, or repairing the harness.
  • K
    kimberly59Sep 7, 2025
    What to do if seed tube sensor dirty or blocked warning comes on Kinze KPM I Measuring Instruments?
    • J
      Jacob JohnsonSep 7, 2025
      If the seed tube sensor dirty or blocked warning appears on your Kinze Measuring Instruments (after calibration, the bar graph keeps blinking for a single row), the seed tube sensor might be dirty or faulty. Try cleaning or replacing the sensor.