TROUBLE SHOOTING 10-3
Check coupler connections. Repair or replace.
Quick disconnect coupler restriction or
coupler "Flow checks"
Refer to "Aeration of Hydraulic Fluid".Aeration of hydraulic fluid
check control valve linkage and repair if
worn/defective.
Control valve linkage binding/defective.
Reduce material load.
Excessive weight in bucket. Material weight
exceeds maximum specified loader capacity.
Increase engine speed to obtain satisfactory
loader operation.
Engine R.P.M. too slow(hydraulic pump
R.P.M. too slow).
Allow hydraulic system to warm up to
operating temperature.
Cold hydraulic fluid.
Check and replenish hydraulic fluid.Low hydraulic fluid level.
Slow or erratic lift
Correct hydraulic hose connections.Hydraulic hoses connected incorrectly.
Lift and/or Bucket
Cylinders operate in
wrong direction relative
to control valve lever
position.
CORRECTIONPOSSIBLE CAUSEPROBLEM