15
The DC receptacle may be used for charging 12 volt automotive-type batteries only. It is not designed
to operate DC motors. Output voltage is 15-30V. DC output will vary according to the position of the
Smart throttle switch.
a. Connect the charging cable to the DC receptacle of the generator and then to the battery terminals.
To prevent the possibility of creating sparks near the battery, connect
the charging cable first to the generator then to the battery.
Disconnect the cable first at the battery.
Before connecting the charging cable to a battery that is installed in a
vehicle, disconnect the vehicle's battery ground cable. Reconnect the
vehicle's ground cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit and sparks if
accidental contact is made between a battery terminal and the
vehicle's frame or body.
Do not attempt to start an automobile engine with the generator still
connected to battery. The generator may be damaged.
Connect the positive battery terminal to the positive charging cord.
Do not reverse the charging cables or serious damage to the
generator and/or battery may occur.
The battery gives off explosive gases: keep sparks, flames and
cigarettes away. Provide adequate ventilation when charging.
The battery contains sulfuric acid (electrolyte). Contact with skin or
eyes may cause severe burns. Wear protective clothing and a face
shield.
A. If electrolyte gets on your skin, flush with water.
B. If electrolytes gets in your eyes, flush with water for at least 15
minutes and call a physician.
Electrolyte is poisonous.
If swallowed, drink large quantities of water or milk and follow with
milk of magnesia or vegetable oil and call a physician.
Keep out of reach of children.
The DC output is to be used to charge batteries only. Serious
damage to the stator windings can occur if connected to a DC motor

Other manuals for Kipor IG3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG3000 and is the answer not in the manual?

Kipor IG3000 Specifications

General IconGeneral
Maximum Power3.0 kW
Fuel TypeGasoline
Rated Voltage230V
Rated Current12.2A
Rated Frequency50Hz
Rated Power2800 watts
Engine Type4-stroke
Fuel Tank Capacity13 L
Starting SystemRecoil/Electric