16
or transformer.
b. Start the generator.
The DC receptacle may be used while the AC power is in use.
The DC receptacle is protected from an overload with a fuse. If the DC circuit is overloaded, the 5
amp fuse will blow and power to the DC receptacle will cease. The red light on the DC panel will
illuminate. The fuse is located to the left of the receptacle and is accessed by snapping open the access
door. Replace the fuse with one of the same capacity. Using a higher rated fuse may cause damage to
the generator alternator.
5.8 Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil
in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm
system will automatically shut down the engine (the engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine the red low oil alarm indictor light will come on when
you operate the starter, and the engine will not run. If this occurs, search for any oil leaks. Add engine
oil to resume normal operation.
Access door
5 amp fuse

Other manuals for Kipor IG3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG3000 and is the answer not in the manual?

Kipor IG3000 Specifications

General IconGeneral
Maximum Power3.0 kW
Fuel TypeGasoline
Rated Voltage230V
Rated Current12.2A
Rated Frequency50Hz
Rated Power2800 watts
Engine Type4-stroke
Fuel Tank Capacity13 L
Starting SystemRecoil/Electric

Related product manuals