SPECIFICATIONS
Types of Data Available
Material level and weight; any process variable available from a 4-20 mA signal *
Historical data
Alarm conditions
Logsofuseraccessandcongurationchanges
Data Access Methods
Over intranet or internet via web browser
Datadownloadtospreadsheetordelimitedle
Automatic transmission to client database in XML format
Alarm Alerts
Anyuser-speciedconditionforlevel,weight,orotherprocessvariables
Malfunction status of connected devices
Alarm conditions viewable via web
Alerts transmitted electronically to e-mail, handheld devices
System Setup
Plug-and-play configuration with most Bindicator and Kistler-Morse
®
systems
Customized units of measure
Frequency of data collection
Usercongurationandaccesspermissions
Device Compatibility
Bindicator Level Devices: GP-4 and Mark-4 Yo-Yo™ (Version 1.05 or higher), Sonotracker™ Ultrasonics,
TDR-2000 Guided Wave Radar (via 4-20 mA input), 4-20mA Input Box
Kistler-Morse Weighing Systems: SVS 2000, Weigh II (Rev B firmware or higher), STX
+
, MVS (Rev G
firmware or higher), Sono II (Rev L firmware or higher); Ultra-wave™ , 4-20 mA Input Box
Communication
Ports
1 Ethernet TCP/IP (RJ45)
3 RS-422/485/232C
Power Supply Requirements 90 VAC to 254 VAC; 40 watts
Operating Temperature
-22° to 125° F (-30° to 52° C)
Humidity: 0 - 100% non-condensing
Enclosure NEMA-4X, Fiberglass Reinforced Plastic
Physical Dimensions
10.5” H x 8.5” W x 6.5” D
(130.2 mm x 215.9 mm x 165.1 mm)
6.5 lbs (2.95 kg)
Mounting hole pattern 10.94” x 6” (278.87 mm x 152.40 mm)
Approvals CE
* A separate ORB 4-20 mA input box is required.
44
97-1167-01 Rev. J
www.kistlermorse.com