TRASH COMPACTOR
INSTALLATION INSTRUCTIONS
KCS-200
INSTALLER: FINAL CHECK LIST
PLACEMENT OF COMPACTOR
cl 1.
Compactor placed in convenient location.
0 2. Adequate space allowed for full drawer opening.
cl 3.
Built-in conversion and installation completed:
a. Properly positioned - Level, Aligned and Square with cabinet opening.
b. Unit snugly positioned in cabinet using leveling legs.
C.
A minimum l/4” clearance MUST BE MAINTAINED between compactor top and
counter top for service accessibility. (See Fig. 2).
ELECTRICAL CONNECTION
cl 1. Properly fused, 115 volt, 60 hertz branch circuit of 15 ampere capacity.
0 2.
q
Compactor properly grounded. (3-Prong grounded receptacle).
3. All connections in conformance with local electrical code.
OPERATIONAL CHECK
Cl 1.
Fully open then close drawer to check drawer operation.
0
2.
Check compacting cycles.
a.
With drawer fully closed, turn key to “start” and allow compactor to run one full
cycle (ram goes down, back up, then stops).
b.
Turn key to “start” a second time, wait approx. 5 seconds then turn key to “stop/
lock” position (ram should stop).
cl 3. c-
Turn key to first position. (ram should return to “up” position and stop).
Check charcoal air filter unit:
a.
With drawer fully closed, push charcoal air filter switch on.
THANK YOU INSTALLER:
1. Complete Installation Check List.
2. Leave all literature (Incls. Check List) for customer.
3. Notify dealer that electrical work is completed.
FOR DETAILED INSTRUCTIONS, FOLLOW METHOD DESCRIBED IN THIS FOLDER
Question and Answer IconNeed help?

Do you have a question about the KitchenAid KCS-200 and is the answer not in the manual?

KitchenAid KCS-200 Specifications

General IconGeneral
BrandKitchenAid
ModelKCS-200
CategoryTrash Compactor
LanguageEnglish

Summary

Installer Final Check List

Placement of Compactor

Ensure compactor is in a convenient location with adequate space for full drawer opening.

Built-in Conversion and Installation

Verify unit is level, aligned, square, snugly positioned, and has 1/4" clearance for service.

Electrical Connection Requirements

Confirm properly fused 115V/60Hz circuit, grounding, and adherence to local electrical codes.

Operational Check Procedures

Test drawer operation, compacting cycles, and charcoal air filter switch function.

Installation Dimensions and Electrical Connection

Electrical Specifications

Details voltage, frequency, operating load, circuit fuse, and wiring code compliance.

Installation Dimensions Overview

Provides key measurements for placement and installation referencing Fig. 1.

Connecting to Electricity

Guide on connecting to a properly grounded 3-prong receptacle and securing the cord.

Receptacle Outlet Grounding

Emphasizes the necessity of a properly grounded outlet for operator safety.

Final Installation Steps

Sliding Compactor into Cavity

Instructions for sliding the unit into place without damaging the plug or receptacle.

Leveling the Compactor

Using leveling feet to ensure the unit is stable and maintains minimum top clearance.

Charcoal Air Filter Installation

Final check for the proper installation of the charcoal air filter unit.

Kickboard Molding Adjustment

Guidance on adjusting or removing kickboard molding for carpet installations.

Related product manuals