EasyManua.ls Logo

KLS Martin maXium smart C - User Manual

KLS Martin maXium smart C
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Front Cover
English
Tested according to:
UL 60601-1:2003
CAN/CSA C22.2 No.601.1-M90
maxium
® smart C Electrosurgery Unit with
maxium
® smart Beam
Instructions for Use
90-046-52-10
Revision 1
Date of Release: 2017-10
Valid from software version V
1.3.35.3017

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the KLS Martin maXium smart C and is the answer not in the manual?

Summary

1 Notices Concerning this Document

1.1 Safety

Non-observance of this document can lead to serious or even lethal patient injury.

1.2 Terms & Acronyms

Provides definitions for technical terms and abbreviations used in the document.

1.3 Document Validity

States the validity of the document from a specific software version.

1.4 Symbols Used in Document

Explains the meaning of symbols and signal words used throughout the manual.

2 Product Liability and Warranty

2.1 General Information

Provides general information about the product and its CE marking.

2.2 Hotline

Contact information for product management and service center.

2.3 Scope of Delivery

Lists the included components for the electrosurgery unit, argon beamer, and equipment cart.

2.4 User’s Inspection

Instructions for checking the goods for completeness and potential damage upon receipt.

2.5 Warranty

Details the terms and conditions of the product warranty.

3 Intended Use

3.1 Intended use of the maxium smart C

Describes the intended use of the maxium® smart C electrosurgery unit.

3.2 Intended use of the maxium smart Beam

Describes the intended use of the maxium® smart Beam accessory.

3.3 Instructions

Provides instructions for proper operation and handling of the device.

4 Working Principles

4.1 Preface

Introduction to the principles of high-frequency electricity in surgery.

4.2 Monopolar application of HF current

Explains the principles of monopolar HF current application in electrosurgery.

4.3 Bipolar application of HF current

Explains the principles of bipolar HF current application in electrosurgery.

5 Risk Minimization and Safety Measures

5.1 Risks from Stray Currents

Discusses risks associated with stray currents, including patient shunts and leakage currents.

5.2 Risks from Current Concentration

Details risks from current concentration in the body and at the neutral electrode.

5.3 Risks from Arcing and Sparking

Covers hazards related to arcing and sparking in electrosurgery and ignition risks.

5.4 Risks from High Voltage

Addresses dangers of neuromuscular stimulation and other risks associated with high voltage.

5.5 Risks from Electromagnetic Interference

Explains risks from electromagnetic interference affecting the unit and active implants.

5.6 Risks from Pressure Vessels and Argon Gas Flow

Covers risks associated with pressure vessels and argon gas flow, including embolisms.

5.7 Additional insufflation for endosurgical applications

Discusses risks of gas insufflation in endosurgical applications, such as pressure increase.

5.8 Miscellaneous

Covers various miscellaneous risks including inadvertent HF emission and device combinations.

6 Functions

6.1 Overview

Provides a general overview of the maxium® smart C's features and capabilities.

6.2 Connections on the Front

Details the front panel connections for monopolar, bipolar, and neutral electrode sockets.

6.3 Connections on the Rear

Describes the rear panel connections for foot switches, interface, serial ports, and bonding.

6.4 Controls

Explains the operation of the ON/OFF key and the touchscreen interface.

7 Accessories

7.1 maxium smart Beam

Details the maxium® smart Beam, an accessory for argon plasma coagulation.

7.2 Instruments, Electrode Handles, and Cables

Information on approved accessories, wear parts, and single-use articles.

8 Installation and Setup

8.1 Standalone Installation of the maxium smart C

Instructions for setting up the maxium® smart C as a standalone unit.

8.2 Installing the maxium smart C with smart Beam

Guide for stacking and connecting the maxium® smart C and maxium® smart Beam components.

8.3 Installation on the maxium smart Cart

Instructions for installing the system components on the maxium® smart Cart.

9 Commissioning and Initial Operation

9.1 General Information

States requirements for personnel using the unit and adherence to instructions.

9.2 Switching on the maxium smart C

Describes the process of switching on the unit and the self-test sequence.

9.3 Switching on the maxium smart Beam

Details the self-test process for the maxium® smart Beam and typical messages.

9.4 Connecting Electrodes

Instructions for examining and connecting active and neutral electrodes.

9.5 Neutral Electrode Application

Provides detailed guidance on applying the neutral electrode to ensure safe operation.

9.6 Argon Filling Level

Explains how the argon filling level is displayed and indicates important information.

9.7 Bipolar Coagulation Auto Functions

Describes automatic activation functions for bipolar coagulation, including delay settings.

9.8 Auto-Start Function Limitations

Highlights limitations and safety aspects of the auto-start function, especially in endoscopy.

10 Using the maxium smart C

10.1 General Information

Overview of device operation, settings via touchscreen, and use of pre-defined programs.

10.2 Channel Selection and Deselection

Explains how to select and deselect working channels on the screen for clarity.

10.3 Setting Working Channel Values

Guide to setting HF output power, current, effect, and activation type for working channels.

10.4 Navigating Programs and Functions

Explains how to navigate through programs and functions using the touchscreen menus.

10.5 Programming Settings

Details how to save, modify, and delete programs for customized settings.

10.6 The Setup Menu

Describes various unit and service settings available in the Setup menu.

11 Currents, Properties, and Technical Data

11.1 Monopolar Cutting Currents

Details monopolar cutting currents like Pure Cut, Blend Cut, Uro Pure Cut, Uro Blend Cut, Soft Cut, and Argon Cut.

11.2 Monopolar Coagulation Currents

Describes monopolar coagulation currents such as Forced Clamp, Forced Prep, Spray, Contact Coag, Forced Coag, Uro Coag.

11.3 Bipolar Cutting Currents

Details bipolar cutting currents like Bipol Pure Cut and Forfex.

11.4 Bipolar Coagulation Currents

Describes bipolar coagulation currents like BiCoag, Neptun.

12 Cleaning and Disinfection

13 Unit Messages and Troubleshooting

13.1 Self-Test Messages

Lists and explains messages that may appear during the unit's self-test.

13.2 Activation Error Messages

Provides troubleshooting steps for messages indicating activation errors.

13.3 Input Feedback Messages

Explains messages related to illegal inputs or settings and how to resolve them.

13.4 Program-Related Messages

Details messages related to program management, such as overwriting or memory full.

13.5 Argon Beamer and Fume Suction System Messages

Lists messages from the argon beamer and fume suction system and their descriptions.

13.6 System Errors

Lists system error messages that the user can resolve independently.

14 Periodic Safety Checks

15 Disposal Information

15.1 Packaging Disposal

Information on how to dispose of or recycle the product packaging.

15.2 Ecological Aspects of Operation

Notes on ecological considerations during product operation.

15.3 Device Disposal

Instructions for the proper disposal of the device according to regulations.

15.4 National Regulations

Highlights the need to observe national regulations for disposal measures.

16 Electromagnetic Compatibility (EMC)

17 Technical Specifications

17.1 Maxium Technical Specifications

Lists the key features and specifications of the maxium® electrosurgery unit.

17.2 Technical Data for maxium smart C

Provides detailed technical data for the maxium® smart C unit.

17.3 Technical Data for maxium smart Beam

Provides detailed technical data for the maxium® smart Beam accessory.

KLS Martin maXium smart C Specifications

General IconGeneral
TypeElectrosurgical unit
Operating Frequency350 kHz
Max. Output Power (Monopolar)400 W
Max. Output Power (Bipolar)120 W
Power OutputAdjustable
DisplayTouch screen
Mains Voltage100-240 V
Mains Frequency50/60 Hz
ConnectivityUSB, Ethernet
TechnologyRadiofrequency (RF)

Related product manuals