CARBON MONOXIDE CANNOT
BE SEEN OR SMELLED BUT CAN
KILL YOU. IF ALARM SIGNAL
SOUNDS: 1. OPERATE TEST/SILENCE
BUTTON. 2. CALL YOUR EMERGENCY
SERVICES (FIRE DEPARTMENT OR
911). 3. IMMEDIATELY MOVE TO
FRESH AIR -OUTDOORS OR BY AN
OPEN DOOR/ WINDOW.
MAINTENANCE AND TESTING:
ALARM IS SEALED, WITH NO
SERVICEABLE PARTS.
BATTERY IS NOT REPLACEABLE.
CONSTANT USE AT HIGH OR LOW
TEMPERATURES OR HIGH
HUMIDITY MAY REDUCE
BATTERY LIFE. TEST
WEEKLY.
GENTLY VACUUM
MONTHLY. TEN YEARS
AFTER INITIAL POWER UP,
THIS UNIT WILL “BEEP”
TWICE EVERY 30
SECONDS, AND “END OF
LIFE - REPLACE UNIT”
WILL APPEAR ON THE
DISPLAY, INDICATING IT IS
TIME TO REPLACE
THE UNIT.
REPLACE IMMEDIATELY! IT
WILL NOT DETECT CO IN THIS
CONDITION.
TO ORDER REPLACEMENT
USER’S MANUAL OR TO
RETURN ALARM CALL
CONSUMER AFFAIRS:
www.knox.com/safety
Manufactured in Mexico
MODEL NO. 7000
SINGLE STATION CO ALARM
KNOX SAFETY,
1601 W. DEER VALLEY RD.
PHOENIX, AZ 85027
WARNING!
HOW TO ACTIVATE ALARM:
1) TO ACTIVATE ALARM, MOVE
SWITCH BELOW TO THE
“ACTIVATED” POSITION.
2) LISTEN FOR ACTIVATION
MESSAGE.
3) TO ENSURE ALARM IS
ACTIVATED, PRESS
“TEST/RESET” BUTTON AND
LISTEN FOR TEST MESSAGE.
HOW TO DEACTIVATE ALARM:
1) TO DEACTIVATE ALARM, USE A
SCREWDRIVER TO BREAK THE
TAB BEHIND THE CROSS-
HATCHED AREA ABOVE, AND
MOVE THE SWITCH TO THE
DEACTIVATE POSITION.
2) LISTEN FOR DEACTIVATION
MESSAGE.
3) ONCE DEACTIVATED, THE
ALARM CANNOT BE REACTIVATED, OR
RE-ATTACHED TO MOUNTING PLATE.
REPLACE IMMEDIATELY. IT WILL NOT
DETECT CO IN THIS CONDITION.
ALARM GUIDE:
Audio Alerts
4 “BEEPS” – CO ALARM
2 “BEEPS” Every
30 Seconds – End of
Life/Replace
1 “BEEP” Every
30 Seconds – Error/Replace
ALARM RESPONSE TIMES:
70 ppm CO Concentration
60-240 minutes
150 ppm CO Concentration
10-50 minutes
400 ppm CO Concentration
4-15 minutes
DEACTIVATED
ACTIVATED
BREAK TAB TO
DEACTIVATE
LED OPERATION:
Green = Normal
Amber = Trouble
Red = Alarm
See User Guide for
more information
Conforms to STD UL2034
5020949
MODEL NO. 7200
SINGLE STATION CO ALARM
120VAC~, 0.01A, 60Hz
ALARM GUIDE:
Audio Alerts
4 “BEEPS” – CO ALARM
2 “BEEPS” Every 30 Seconds – End of Life/Replace
1 “BEEP” Every 30 Seconds – Error/Replace
ALARM RESPONSE TIMES:
70 ppm CO Concentration/60-240 minutes
150 ppm CO Concentration/10-50 minutes
400 ppm CO Concentration/4-15 minutes
CARBON MONOXIDE CANNOT
BE SEEN OR SMELLED BUT CAN
KILL YOU. IF ALARM SIGNAL
SOUNDS: 1. OPERATE TEST/SILENCE
BUTTON. 2. CALL YOUR EMERGENCY
SERVICES (FIRE DEPARTMENT OR
911). 3. IMMEDIATELY MOVE TO
FRESH AIR -OUTDOORS OR BY AN
OPEN DOOR/ WINDOW.
MAINTENANCE AND TESTING:
ALARM IS SEALED, WITH NO
SERVICEABLE PARTS.
BATTERY IS NOT REPLACEABLE.
CONSTANT USE AT HIGH OR LOW
TEMPERATURES OR HIGH
HUMIDITY MAY REDUCE
BATTERY LIFE. TEST WEEKLY.
GENTLY VACUUM MONTHLY. TEN
YEARS AFTER INITIAL POWER UP,
THIS UNIT WILL “BEEP” TWICE
EVERY 30 SECONDS, AND “END
OF LIFE - REPLACE UNIT” WILL
APPEAR ON THE DISPLAY,
INDICATING IT IS TIME TO
REPLACE THE UNIT.
REPLACE IMMEDIATELY! IT
WILL NOT DETECT CO IN THIS
CONDITION.
TO ORDER REPLACEMENT
USER’S MANUAL OR TO
RETURN ALARM CALL
CONSUMER AFFAIRS:
www.knox.com/safety
Manufactured in Mexico
WARNING!
HOW TO ACTIVATE
ALARM:
1) TO ACTIVATE
ALARM, MOVE
SWITCH ABOVE TO
THE “ACTIVATED”
POSITION.
2) LISTEN FOR
ACTIVATION
MESSAGE.
3) TO ENSURE ALARM
IS ACTIVATED,
PRESS “TEST/
RESET” BUTTON
AND LISTEN FOR
TEST MESSAGE.
HOW TO DEACTIVATE
ALARM:
1) TO DEACTIVATE ALARM,
USE A SCREWDRIVER
TO REMOVE TAB IN
CROSS-HATCHED
AREA ABOVE.
2) LISTEN FOR
DEACTIVATION
MESSAGE.
3) ONCE DEACTIVATED,
THE ALARM CANNOT BE
REACTIVATED.REPLACE
IMMEDIATELY. IT WILL
NOT DETECT CO
IN THIS CONDITION.
DEACTIVATED
ACTIVATED
BREAK TAB TO
DEACTIVATE
KNOX SAFETY
1601 W. DEER VALLEY RD.
PHOENIX, AZ 85027
Conforms to STD UL2034
5020949
LED OPERATION:
Green = Normal
Amber = Trouble
Red = Alarm
See User Guide for more information
Parts of Your CO Alarm –
Model 7000
1. Alarm horn/Speaker
(behind cover) -
communicates alerts
2. Display – for change in status
messages and alerts
3. Peak Button – registers
highest level of CO detected
4. LED
5. Test/Reset button – use for
weekly testing or to
temporarily reset/silence
notifications
6. Status – provides audible and
visual confirmation of unit
status
7. Activation and Deactivation
Tab – on the rear of the unit
HUSH
END
EXIT
VENTILATE
REPLACE
DANGER
CALL
CO LEVEL
CO LEVEL PPM
ERROR
PEAK
TEST/
RESET
STATUS
1
2
3
4
5
6
7
HUSH
END
EXIT
VENTILATE
REPLACE
DANGER
CALL
CO LEVEL
CO LEVEL PPM
ERROR
PEAK
TEST/
RESET
STATUS
1
2
3
4
5
6
7
8
Parts of Your CO Alarm –
Model 7200
1. Alarm horn/Speaker
(behind cover) -
communicates alerts
2. Display – for change in status
messages and alerts
3. Peak Button – registers
highest level of CO detected
4. LED
5. Test/Reset button – use for
weekly testing or to
temporarily reset/silence
notifications
6. Status – provides audible and
visual confirmation of unit
status
7. Rotating AC Plug -on the rear
of the unit.
8. Activation and Deactivation
Tab – on the rear of the unit
3