TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The motor will not
run.
1. Tank pressure exceeds the
preset pressure switch limit.
2. The fuse is blown or the circuit
breaker tripped.
3. The check valve is stuck in the
open position.
4. The wire gauge in the cord is
wrong or the extension cord
length is excessive.
5. There are loose electrical
connections.
6. The motor’s thermal overload
protection has tripped.
7. The motor or capacitor is
defective.
1. The motor will start automatically
when the tank pressure drops
below the tank cut-in pressure.
2. Replace the blown fuse or reset
the circuit breaker. Do not use a
fuse or circuit breaker with a higher
circuit.
Check for proper fuse; type T fuse
is acceptable.
Check for low voltage and proper
extension cord size.
Disconnect other applications from
the circuit. Operate the compressor
on a dedicated circuit.
3. Remove and clean or replace.
4. Check for proper gauge (18 AWG)
and extension cord length (72 ft).
5. Contact customer service.
6. Turn the air compressor off, unplug
7. Have the compressor serviced by a
qualified technician.
the power cord and wait until the
motor has cooled down. Plug in
the power cord only after the motor
has cooled down, waiting
thermal overload protector has
the
recovered.
The pressure relief
valve opens.
1. The tank pressure exceeds the
normal rating pressure.
2. The pressure switch is stuck.
Replace the compressor.
2. Replace the compressor.
1.