Kobalt LK20175 - User Manual

Kobalt LK20175
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
JW1827
OIL-FREE AIR
COMPRESSOR
ITEM #0905516
MODEL #LK20175
Español p. 22
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-888-3KOBALT (1-888-356-2258), 8 a.m. - 8 p.m., EST,
Monday - Friday.
ATTACH YOUR RECEIPT HERE
Serial Number Purchase Date

Questions and Answers

  • T
    Tammy SalasAug 15, 2025
    Why Kobalt LK20175 does not run?
    • B
      barbertammyAug 16, 2025
      If your Kobalt Air Compressor isn't running, there could be several reasons. First, ensure it's properly plugged in and the power switch is in the ON position. Check the extension cord for proper use. Also, a fuse might have blown or a breaker tripped at the power supply, so replace the fuse or reset the breaker. If the thermal overload is open, unplug the compressor and wait for it to cool down. The motor should restart automatically. If the tank is full, the compressor will start when the pressure drops. If none of these solutions work, the pressure switch may be bad and require replacement.
  • R
    Robert MooreAug 19, 2025
    Why air pressure drops when Kobalt LK20175 shuts off?
    • T
      Troy SmithAug 19, 2025
      If the air pressure drops in your Kobalt Air Compressor after it shuts off, check all connections (fittings, tubing, etc.) with soapy water for leaks, indicated by bubbles, and tighten any loose connections. Also, tighten the drain valve. If these steps don't solve the issue, the check valve may be leaking, requiring professional service.
  • K
    kimberly83Aug 21, 2025
    Why Kobalt LK20175 Air Compressor motor hums but does not run?
    • A
      Ana GoodmanAug 21, 2025
      If your Kobalt Air Compressor motor hums but doesn't run or runs slowly, the voltage from the power supply might be low; check it with a voltmeter. Also, ensure you're using the correct wire gauge and length for the extension cord. If these aren't the issue, the motor winding or the unloader/check valve may be defective, requiring a visit to a service center.
  • C
    Colin GrossAug 25, 2025
    Why thermal overload protector cuts out repeatedly on Kobalt LK20175?
    • R
      rodneychangAug 26, 2025
      If the thermal overload protector on your Kobalt Air Compressor cuts out repeatedly, check the voltage from the power supply with a voltmeter. Ensure the compressor is in a well-ventilated area to prevent overheating. Also, verify that you are using the correct gauge wire and cord length.
  • E
    Emily OwensAug 28, 2025
    What to do if Kobalt LK20175 runs continuously?
    • B
      Brittany MillerAug 28, 2025
      If your Kobalt Air Compressor runs continuously, first check that the tank drain valve is closed. If it is, the pressure switch might be defective, requiring a visit to a service center. Also, consider whether the usage is excessive; the compressor might not be large enough for the tool's air requirements, so reduce the tool run-time.
  • D
    Douglas KingAug 30, 2025
    How to fix air leaking from Kobalt LK20175?
    • S
      Samuel BautistaAug 31, 2025
      If air is leaking from your Kobalt Air Compressor, ensure all hose connections are properly sealed with thread sealing tape and tightened. If the air hose is broken or damaged, it will need to be replaced.
  • K
    Kristen BarrettSep 3, 2025
    Why Kobalt LK20175 Air Compressor air output is lower than normal?
    • M
      medinajacobSep 3, 2025
      If the air output of your Kobalt Air Compressor is lower than normal, the inlet valves might be broken, requiring a visit to a service center. Also, check the connections for leaks and apply thread sealing tape to fittings before tightening.
  • A
    Anthony LopezSep 5, 2025
    What to do if fuses blow repeatedly on Kobalt LK20175 Air Compressor?
    • C
      crosbyzacharySep 6, 2025
      If the fuses blow or the circuit breaker trips repeatedly on your Kobalt Air Compressor, make sure the fuse or breaker at the power supply is the correct size and type. Use only time-delay fuses to avoid overloading the circuit. Try disconnecting other electrical appliances from the circuit or operate the compressor on its own branch circuit. Also, ensure you are using the correct wire gauge and length of extension cord. If the problem persists, the unloader or check valve might be defective, requiring service.
  • S
    Stephen LeeSep 9, 2025
    How to reduce moisture in Kobalt LK20175 discharge?
    • J
      Jordan WoodardSep 9, 2025
      If there is excessive moisture in the air discharge from your Kobalt Air Compressor, it may be due to excessive water in the air tank; drain the tank to remove the water. High humidity can also cause this issue; move the compressor to an area with less humidity or use an air line filter to reduce moisture discharge.
  • T
    Tina VazquezSep 12, 2025
    How to stop Kobalt Air Compressor from vibrating?
    • S
      Sarah LawsonSep 12, 2025
      If your Kobalt Air Compressor vibrates, check and tighten the compressor mounting bolts.

Summary

Safety Information and Rules

Safety Symbols and General Rules

Explains risk levels using signal words and provides essential safety rules for operation.

Personal Safety and Tool Care

Personal Safety Precautions

Guidelines for user protection regarding attire, alertness, and equipment during operation.

Tool Use and Care

Instructions for proper usage, maintenance, and avoiding damage to the tool.

Service and Specific Safety Rules

Service Requirements

Specifies that service and maintenance must be performed by qualified personnel.

Specific Safety Rules

Details specific hazards and precautions for compressor operation and use.

Operating Instructions

Applications

Describes various uses for air compressors and specific applications of this model.

How to Use Your Air Compressor

Step-by-step guide for operating the air compressor safely.

Breaking in the Pump

Procedure for the initial run-in period of the pump.

Draining the Tank

Instructions for daily draining of moisture from the tank.

Checking the Safety Valve

Procedure for testing the safety valve's functionality.

End of Operation and Storage

Steps for safely shutting down and storing the compressor.

Care and Maintenance

General Maintenance

Routine checks and cleaning procedures for the compressor.

Lubrication

Information on the lubrication of the unit's bearings.

Troubleshooting

Compressor Does Not Run

Possible causes and corrective actions for a non-operational compressor.

Motor Hums, But Doesnt Run or Runs Slowly

Identifies issues causing motor malfunction and solutions.

Troubleshooting Common Issues

Diagnoses and fixes for pressure loss, moisture, leaks, continuous operation, vibration, and low output.

Warranty Information

1-Year Limited Guarantee

Outlines the terms and duration of the product warranty.

Conditions and Limitations

Specifies the terms and exclusions of the warranty.

Replacement Parts List

Kobalt LK20175 Specifications