TLG2000 Signal Controller Instruction Manual
Page 10 of 20
Term Function Note Term Function Note
1 Earth Ships ground 41 Digital common 0V DC to LED in switch
2 not used 42 DC to external switch
DC supply for external switches/LED’s only.
No other load permitted!
3 not used 43
Input for manual activation of
TYFON
See fig 6, 7 or 8.
4 TYFON Active, Yes
See fig 1.
Unfused output.
44
Input for manual activation of
MORSE LIGHT
See fig 8.
5 TYFON Active, No 45
Input for automatic activation
of TYFON
See fig 6, 7 or 8.
6 TYFON Active, Com 46 Dimmer output to switch LED Max load 100 mA.
7
Output to Fore TYFON > 100m See fig 2
47
Input for “General Emergency
Alarm” activation
See fig 6, 7 or 8.
8 48
Input for “Abandon Ship”
activation
See fig 6, 7 or 8.
9
Output to Fore TYFON <= 100m See fig 2
49 Input for PA interupt See fig 9.
10 50 Digital common 0V DC to LED in switch
11
Output to Aft TYFON See fig 2
51 not used
12 52 not used
13
Mains for TYFON 24V DC or 115...230V AC
53 not used
14
21
Mains for TLG2000
0V
22 + 24 V
23
GEA active
See fig 3.
Unfused output.
24
25
Output to GONG See fig 4
26
27
Output to BELL See fig 4
28
29
Mains BELL and GONG 24V DC or 115...230V AC
30
31
Output to MORSE LIGHT See fig 5
32
33
Mains for MORSE LIGHT 24V DC or 115...230V AC
34
4
5
6
7, 9 or 11
8, 10 or 12
13
14
+
+
23
24
25 or 27
26 or 28
29
30
+
+
31
32
33
34
+
+
Fig 1.
Fig 2.
Fig 3.
Fig 4.
Fig 5.
Outputs
42
43, 44, 45,
41
23
24
X1
X2
42
43, 44, 45,
41
46
23
24
X1
X2
42
43, 44, 45,
47 or 48
23
24
Fig 6.
Switch with built-in LED.
Type TL - 85, TL - 85GEA
or TL - 85AS
Fig 7.
Switch with built-in LED
connected to dimmer.
Type TL - 85, TL - 85GEA
or TL - 85AS
Fig 8.
Type TL - 70, TL - 80,
TL - 80GEA or TL - 80AS.
Inputs
42
49
Fig 9.
Rear side of the control unit
Description of I/O
external side external sideinternal side internal side
1
2
3
4
5
6
7
8
9
10
11
12
13
14
41
42
43
44
45
46
47
48
49
50
51
52
53
22
23
24
25
26
27
28
29
30
31
32
33
34
Serial no.
PE, ships GND
not used
not used
Tyfon Active, Yes
Tyfon Active, No
Tyfon Active, Com
Output
Fore Tyfon <=100m
Output
Fore Tyfon >100m
Output
Aft Tyfon
Mains for
TYFON
Manual switch, Tyfon
Manual switch, morse light
Auto switch, Tyfon
GEA
Abandon Ship
PA interupt
Dig Com
DC to switch
Power supplyfor TLG2000
24V DC
+
0V
GEA active
Output
Gong
Output
Bell
Output
morse light
Mains
morse light
Mains
Bell & Gong
not used
not used
not used
Dimmer to switch LED
Dig Com
1
14
13
12
11
10
9
8
7
6
5
4
3
2
41 42
43 44
45 46 47
48
49 50 51
52 53
34
33
32 31 30
29
28
27
26
25 24
23 22
21
Software
version.