Read and follow all instructions; contact Lytron for questions; disconnect power before servicing.
Avoid damaged cords, use qualified technicians, proper grounding, no automotive antifreeze, avoid outdoor use.
Handle with care, drain for transport/storage, observe warning labels, do not operate damaged or empty units.
Details thermal capacity, BTU/hr, voltage, frequency, and full load amps for models.
Lists compressor size, refrigerant type, temperature stability, and operating environment.
Specifies coolant temperature range, reservoir capacity, dimensions, and weight.
Identifies display elements like temperature, status indicators, and buttons.
Explains functions of the ON/OFF, SET, UP, and DOWN keys for operation.
Defines meanings of indicators like Temperature Set Point, Pressure, Cooling, Low Flow, and Alarms.
Recommends filtered water, requires depressant below 10°C, warns against automotive antifreeze and high minerals.
Advises on placement for airflow, proximity to heat load, and clearance requirements.
Guides on coolant port identification, tubing diameter, length, material, and thermal insulation.
Steps for attaching lines, fitting types, checking for leaks, and filling reservoir.
Lists conditions requiring pump priming: initial startup, after draining, or new pump installation.
Details opening the valve, starting the chiller, and closing the valve once flow is observed.
Explains disconnecting the supply line or using a wet vac for priming.
Emphasizes proper grounding to prevent electrical hazards and damage.
Steps to turn on the unit, adjust set points, check coolant level, and inspect for leaks.
Advises that qualified technicians must perform internal service and maintenance.
Provides guidelines for inspecting noise level, leakage, coolant level, pump, fan, and condenser fins.
Recommends using an algae inhibitor to prevent growth in the reservoir.
Emphasizes disconnecting power, using labeled containers, and following disposal laws.
Detailed steps using a wet/vac to remove fluid from reservoir and connections.
Steps for draining without a wet/vac, using gravity and a bucket.
Explains Err 01 (initialization) and Err 02 (RTD) errors and troubleshooting.
Details Err 03 (operational), Err 04 (low flow), and Err 05 (remote start) errors.
Explains Err 07 (auto temp shut down) and its function.
Addresses problems like no start, short cycling, low flow, low voltage, and excessive noise.
Covers high pressure, noisy compressor, noisy pump motor, and motor overheating.
Troubleshoots persistent audible alarms and low reservoir level indications.
Addresses low coolant flow, temperature alarms, and incorrect temperature readings.
Covers high recirculating pressure, dim startup display, and offset correction.
Defines warranty period, scope of coverage, and exclusions for defects and damages.
States Lytron's exclusion of liability for incidental, consequential damages, and unauthorized repairs.