TP-6334 9/04 Scheduled Maintenance 11
Service Schedule, continued
Perform Service at Intervals Indicated (X)
Reference
Section
Before
Starting
After
50 Hrs
or
1Month
Every
100 Hrs
or
3 Months
Every
300 Hrs
or
6 Months
Every
500 Hrs
or
Yearly
INTAKE/EXHAUST SYSTEM
Inspect the exhaust system components * 3.7 X
Check the exhaust gas condition 3.7
X
(during
operation)
Inspect and clean the air cleaner element
3.6 X
(Weekly)
Replace the air cleaner element 3.6 X
Inspect the complete exhaust system ] 3.7 X
ELECTRICAL SYSTEM
Keep the battery charged and in good condition 3.10 X
Check and tighten electrical connections X
Clean the battery cables *
As
required
ENGINE AND MOUNTING
Check for water, fuel, coolant, and oil leakage *[ X
Retighten all nuts and bolts As
required
Check tightness of mounting bolts/vibromounts
X
(200 hrs)
REMOTE CONTROL SYSTEM
Check the remote control operation
X
(break-in
period)
X
GENERATOR
Test run the generator set 2.3
X
(weekly)
Blow dust out of the generator * 3.1 X
Clean slip rings and inspect brushes *
X
(1000 hrs)
* Consult your local distributor/dealer for service.
[ Read WARNING found at the beginning of manual regarding moving parts.
] Should be performed by your local distributor/dealer.
Consult battery manufacturer’s instructions.