What to do if there is air in the fuel system of my Kohler Portable Generator?
- BbdavisSep 1, 2025
If there is air in the fuel system of your Kohler Portable Generator, bleed the diesel fuel system. The cause is air in the fuel system.

What to do if there is air in the fuel system of my Kohler Portable Generator?
If there is air in the fuel system of your Kohler Portable Generator, bleed the diesel fuel system. The cause is air in the fuel system.
What to do if my Kohler 17EFKOZD breaker is not charged?
Verify that the motor operator is receiving voltage at the appropriate contacts, allowing it to wind the spring.
How to fix a faulty ground connection on my Kohler 17EFKOZD Portable Generator?
If you find a faulty ground connection in your Kohler Portable Generator, clean and retighten the connection. The cause is a faulty ground connection.
How to fix CB trip relay wired as normally open in Kohler Portable Generator?
Check that the CB trip relay is wired to hold a trip on the breaker when the relay is not energized.
How to fix intermittent connection in PGEN wiring in Kohler 17EFKOZD?
Confirm that there are no loose wiring connections or “whiskers” at the PGEN terminal blocks. Using “Fork”, “ring”, or “crow’s feet” connectors for terminal block connections is preferable.
How to resolve breaker status feedback is not valid, no bus sensing in Kohler 17EFKOZD Portable Generator?
Verify the wiring on the circuit breaker to ensure it is connected correctly. Verify bus wiring for all nodes. Verify the generator output is connected to the line side of the generator breaker.
What to do if my Kohler 17EFKOZD Portable Generator shuts down due to low oil pressure?
If your Kohler Portable Generator experiences a low oil pressure shutdown, check the oil level. This is due to low oil pressure shutdown.
What to do if my Kohler Portable Generator is experiencing an engine overload?
If your Kohler Portable Generator experiences an engine overload, reduce the electrical load. The cause is engine overload.
How to fix loose or corroded battery connections on a Kohler 17EFKOZD Portable Generator?
If the battery connections of your Kohler Portable Generator are loose, corroded, or incorrect, verify that the battery connections are correct, clean, and tight. The cause of this problem is that the battery connections are loose, corroded, or incorrect.
What to do if my Kohler Portable Generator runs out of fuel or the fuel valve is off?
If your Kohler Portable Generator's fuel tank is empty or the fuel valve is shut off, add fuel and move the fuel valve to the ON position. This is because the fuel tank is either empty, or the fuel valve is shut off.
| Brand | Kohler |
|---|---|
| Model | 17EFKOZD |
| Category | Portable Generator |
| Language | English |
Steps to perform before starting the generator set.
Information on system events, warnings, and shutdowns.
Procedures for starting, stopping, and operating the generator set.
Warning and procedure to prevent accidental generator start.
Precautions related to fire hazards from fuel and engine operation.
Warnings and guidance concerning carbon monoxide hazards from exhaust.
Safety precautions for handling and using explosive fuel vapors.
Dangers associated with electrical voltage and moving mechanical parts.
Warnings about potential burns from hot engine and exhaust components.
Maintenance tasks and intervals for specific generator models.
Maintenance tasks and intervals for specific generator models.
A chart to diagnose and resolve issues related to the controller display and voltage regulation.