TP-5695 12/93 Operation 2-7
Remote Start and Four-Meter
Panel Kit
Allows starting-stopping from a location remote of the
generator set. The illuminated gauges include a DC
voltmeter, engine oil pressure gauge, water
temperature gauge, and generator running time
hourmeter. Generator sets come equipped with a 6-pin
connector on controller bottom for connection of the kit.
See Figure 2-7 for remote start and four-meter panel
features.
Start/Stop Switch is a rocker-type switch with ON
light used to start and stop the generator set.
DC Voltmeter measures voltage of starting battery(ies).
Normal battery operating range is 12--14 volts.
Engine Oil Pressure Gauge measures engine oil
pressure. Normal engine operating range is 30--50 psi
(207--345 kPa).
NOTE
During the engine break-in period, it is normal for the
engine to produce higher oil pressure readings.
Water Temperature Gauge measures engine coolant
temperature. Normal engine operating range is
170--195_ F (77--91_ C).
Hourmeter records total generator set operating hours
for reference in maintenance scheduling.
1
2
6
5
3
4
1. Engine Oil Pressure
2. Hourmeter
3. Voltmeter
4. Water Temperature
5. Start/Stop Switch
6. ON Light
1-830
Figure 2-7. Remote Start and Four-Meter Features