EasyManuals Logo

Kohler 48RCLB/C User Manual

Kohler 48RCLB/C
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
TP-7102 9/21 19Section 2 Generator Set Operation
2. Press the Select button to go to the main menu.
See Figure 2-2.
3. Press the down arrow button to step to the Genset
System menu.
4. Press the Select button to enter the Genset system
menu. See Figure 2-3.
5. Use the down arrow button to step to the next
Exercise menu.
6. Press the Select button. The setting flashes to
show that it can be changed. For example, the hour
flashes to show that the hour can be changed.
7. Press the UP or Down arrow buttons to change the
setting.
8. Press the Select button to save the setting and
move to the next. For example, save the hour
setting and move to minutes.
9. Repeat steps 5 through 8 to change the next item
on the line until the desired settings are displayed.
10. Press Select to save after all settings have been
selected. Settings will stop flashing.
11. If the generator set is connected to a Kohlerr Model
RXT transfer switch, the exercise can be changed
to a loaded exercise. Set the Exercise Mode to
loaded full speed, unloaded full speed, or unloaded
cycle as shown in Figure 2-3.
12. Set the exercise frequency (weekly or every two
weeks). Weekly exercises are recommended.
13. Press the down arrow button to step to the Return
menu. Press the Select button to retur n to the m ain
menu.
14. Check that the AUTO LED is lit. The generator set
must be in automatic mode for the exercise to run
as scheduled.
After a scheduled exercise run, the next exercise time
and date will be updated automatically based on the
Exercise Frequency setting.
Other transfer switches: For a loaded exercise with a
transfer switch other than a Kohlerr Model RXT,
program the exercise at the transfer switch controller.
Refer to the transfer switch operation manual for
instructions.
Overview - - >
1.2 h
Engine - - >
Metering
tp6810
Generator- - >
Metering
Genset - - >
Information
Genset - - >
Run Time
Date - - >
and Time
ATS - - >
Configuration
Genset - - >
System
Event Log- - >
Load - - >
Control
PIM - - >
Status
Network - - >
Information
Status
Displays
ATS - - >
Status
Figure 2-2 RDC2 Main Menu

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 48RCLB/C and is the answer not in the manual?

Kohler 48RCLB/C Specifications

General IconGeneral
BrandKohler
Model48RCLB/C
CategoryPortable Generator
LanguageEnglish

Related product manuals