Maintenance Schedule
These required maintenance procedures should be performed at the frequency stated in the table. They should also
be included as part of any seasonal tune-up.
4. Remove the dipstick and check the oil level.
The oil level should be up to, but not over, the “F”
mark on the dipstick. See Figure 7.
Operating
Range
“F” Mark
¹Perform these maintenance procedures more frequently under extremely dusty, dirty conditions.
2
Only required for Denso starters. Not necessary on Delco starters. Have a Kohler Engine Service Dealer perform
this service.
Check Oil Level
The importance of checking and maintaining the proper
oil level in the crankcase cannot be overemphasized.
Check oil BEFORE EACH USE as follows:
1. Make sure the engine is stopped, level, and is cool
so the oil has had time to drain into the sump.
2. To keep dirt, grass clippings, etc., out of the
engine, clean the area around the oil fill cap/
dipstick before removing it.
3. Remove the oil fill cap/dipstick; wipe oil off.
For engines with a press-on style dipstick:
Reinsert the dipstick into the tube and press onto
the tube. See Figure 6.
For engines with a thread-on style dipstick:
Reinsert the dipstick into the tube and rest the oil
fill cap on the tube. Do not thread the cap onto the
tube. See Figure 6.
Figure 6. Dipstick Styles.
Daily or Before
Starting Engine
Maintenance RequiredFrequency
Fill fuel tank.
Check oil level.
Check air cleaner for dirty¹, loose, or damaged parts.
Check air intake and cooling areas, clean as necessary¹.
Service precleaner element¹.
Every 25 Hours
Replace air cleaner element¹.
Change oil.
Remove cooling shrouds and clean cooling areas¹.
Every 100 Hours
Change oil filter.
Check spark plug condition and gap.
Replace fuel filter.
Every 200 Hours
Annually or
Every 500 Hours
Have bendix starter drive serviced².
Have solenoid shift starter disassembled and cleaned
2
.
Every 50 Hours
Check gear reduction unit.
Figure 7. Oil Level Dipstick.
5. If the level is low, add oil of the proper type, up to
the “F” mark on the dipstick. (Refer to Oil Type on
page 4.) Always check the level with the dipstick
before adding more oil.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the “L”
mark or over the “F” mark on the dipstick.
Press-On
Thread-On

Other manuals for Kohler COMMAND CH15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler COMMAND CH15 and is the answer not in the manual?

Kohler COMMAND CH15 Specifications

General IconGeneral
BrandKohler
ModelCOMMAND CH15
CategoryEngine
LanguageEnglish

Related product manuals