EasyManua.ls Logo

Kohler COMMAND CH18-745 - Tighten Starter Housing and Baffle Screws; Install Metal Grass Screen

Kohler COMMAND CH18-745
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.18
Section 11
Reassembly
Figure 11-65. Tighten Baffle Mounting Screws.
6. The metal grass screen can now be attached to
the supports.
Figure 11-64. Tighten Short Screws to Torque
Specified.
Figure 11-66. Installing Metal Type Grass Screen.
7. Torque the four breather cover screws to 7.3 N·m
(65 in. lb.) in the sequence shown in Figure
11-67.
4. If the rectifier-regulator was not removed, attach
the ground wire or metal grounding bracket for the
rectifier-regulator, using the silver colored screw
and washer, to the lower blower housing hole.
See Figure 11-63.
Figure 11-63. Ground Lead Details.
5. Tighten all of the shrouding fasteners. Torque the
blower housing screws to 6.2 N·m (55 in. lb.) in a
new hole, or to 4.0 N·m (35 in. lb.) in a used hole.
Torque the shorter M5 side baffle screws to 4.0
N·m (35 in. lb.). See Figure 11-64. Torque the
upper M5 side baffle screws (into cylinder head)
to 6.2 N·m (55 in. lb.) in a new hole, or to 4.0 N·m
(35 in. lb.) in a used hole. Torque the two rear M6
baffle mounting screws to 10.7 N·m (95 in. lb.) in
a new hole, or to 7.3 N·m (65 in. lb.) in a used
hole. See Figure 11-65.

Related product manuals