11.22
Section 11
Reassembly
Figure 11-68. Installing Air Cleaner Cover.
Install Electric Starter
Electric Starter (Bendix Drive or Solenoid Shift)
1. Install the starter and secure with the two hex.
ange screws. If there were spacers on the
mounting screws, be sure they are reinstalled.
Torque the screws to 15.3 N·m (135 in. lb.). See
Figure 11-69.
Figure 11-69. Installing Bendix Drive Starter.
2. Connect the starter leads to the terminals on the
electric starter and/or solenoid.
Install Retractable Starter
1. Install the retractable starter and ve hex. ange
screws to blower housing. Leave the screws
slightly loose.
Figure 11-70. Installing Retractable Starter.
Install Muf er
1. Install the gasket, muf er, and hex. ange nuts
to the exhaust port studs. Leave the nuts slightly
loose. See Figure 11-71. Start the two hex. ange
screws that fasten the muf er to the bracket. See
Figure 11-72.
Hex. Flange
Screws
Figure 11-71. Install Muf er.
2. Torque the hex. ange nuts to 24.4 N·m
(216 in. lb.). Tighten the hex. ange screws
securely.
Knob
Air Cleaner Cover
Electric
Starter
Stud
Terminal
Muf er
Hex. Flange Nuts
Gasket
6. Install the air cleaner cover and tighten the knob
securely. See Figure 11-68.
2. Pull the starter handle out until the pawls
engage in the drive cup. Hold the handle in this
position and tighten the screws securely. See
Figure 11-70.