10
10.15
Section 10
Reassembly
Figure 10-51. Installing Screws (Locations 3 and
4).
7. Install the inner ba es using the two remaining
hex ange screws (see Figures 10-52 and 10-53)
and nger tighten. Do not torque the screws at
this time; they will be tightened a er the blower
housing and outer ba es are installed.
Figure 10-53. Finger Tightening Remaining Cover
Screws.
Install Oil Temperature Sensor
NOTE: Ensure part is clean, undamaged and free of
debris and make sure the electrical connector
has the seal in place.
1. Lightly oil the oil temperature sensor O-ring
and install the oil temperature sensor into the
breather cover.
2. Torque the sensor to 7.3 N·m (65 in. lb.). See
Figure 10-54.
Figure 10-54. Torque Oil Temperature Sensor.
3. Push the electrical connector on the oil
temperature sensor making sure a good
connection is made.
Install Oil Sentry™ (If So Equipped)
1. Apply pipe sealant with Te on
®
(Loctite
®
592
PST
®
Thread Sealant or equivalent) to the threads
of the Oil Sentry
switch and install it into the
breather cover. See Figure 10-55. Torque to
4.5 N·m (40 in. lb.).
Figure 10-52. Installing Inner Baf es.
Figure 10-55. Oil Sentry
TM
Switch (If So Equipped).