EasyManua.ls Logo

Kohler Command PRO ECH650 - Reconnect Rectifier-Regulator; Install Grass Screen

Kohler Command PRO ECH650
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
10.17
Section 10
Reassembly
Figure 10-59. Breather Cover Fastener Torque
Sequence.
Reconnect Recti er-Regulator
1. Install the recti er-regulator in the blower
housing if removed previously, then secure
grounding bracket against the outer side of the
recti er-regulator with a silver screw. See Figure
10-60.
Figure 10-60. Recti er-Regulator Ground Details.
2. Torque the two black recti er-regulator hex
ange screws to 1.4 N·m (12.6 in. lb.) and
the silver ground strap hex ange screw to
2.8 N·m (25 in. lb.) into new holes or 2.3 N·m
(20 in. lb.) into used holes.
3. Connect the plug to the recti er-regulator. If the
purple wire was removed, verify the locking
tang is raised on the terminal and push the wire
terminal into the plug prior to connecting to the
recti er-regulator. See Figure 10-61.
NOTE: The recti er-regulator middle terminal (B+)
is o set (not equally spaced) from the outer
terminals (AC). Verify the recti er-regulator
plug is assembled to match the terminal
o set of the recti er-regulator.
1&5
2
3
4
Figure 10-61. Attaching Recti er-Regulator Plug.
Install Grass Screen
Metal Grass Screen
1. Verify the locating tabs on the back of the fan are
inserted into the locating holes on the ywheel.
2. To assist assembly, nd four intake manifold
studs with M6 thread at least 100 mm in length to
be used as guide pins. Insert the intake manifold
studs through the cooling fan mounting holes
and thread them 4 or 5 turns into the ywheel.
3. Install a spring washer on each stud with the
concave side down toward the cooling fan. See
Figure 10-62.
Figure 10-62. Spring Washer with Concave Side
Down.
Spring Washer

Related product manuals