EasyManuals Logo

Kohler Command PRO ECH730 User Manual

Kohler Command PRO ECH730
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
9.7
Section 9
Inspection and Reconditioning
9
Excessive Combustion Temperatures: The white
deposits seen here indicate very high combustion
emperatures, usually due to a lean fuel mixture.
Gum: Gum deposits usually result from using stale
gasoline. Gum is a prevalent cause of valve sticking.
The cure is to ream the valve guides and clean or
replace the valves, depending on their condition.
Stem Corrosion: Moisture in fuel or from
condensation are the most common causes of valve
stem corrosion. Condensation occurs from improper
preservation during storage and when engine is
repeatedly stopped before it has a chance to reach
normal operating temperatures. Replace corroded
valves.
Overheating: An exhaust valve subject to overheating
will have a dark discoloration in the area above the
valve guide. Worn guides and faulty valve springs
may cause this condition. Also check for clogged air
intake, and blocked ns when this condition is noted.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Command PRO ECH730 and is the answer not in the manual?

Kohler Command PRO ECH730 Specifications

General IconGeneral
BrandKohler
ModelCommand PRO ECH730
CategoryCrankshaft
LanguageEnglish

Related product manuals