8.9
Section 8
Disassembly
8
Figure 8-31. Removing Blower Housing.
Remove Oil Sentry™
1. Disconnect the lead from the Oil Sentry™ switch.
2. Remove the Oil Sentry™ switch from the
breather cover. See Figure 8-32.
Figure 8-32. Removing Oil Sentry™ Switch.
NOTE: This is optional. Removing the Oil Sentry is
not required to remove the breather cover.
Remove Inner Baf es and Breather Cover
1. Remove the four hex ange screws securing the
inner ba es to the crankcase.
2. Remove the inner (valley) ba es. See Figure 8-33.
Figure 8-34. Remove the Oil Temperature Sensor.
4. Remove the two remaining hex ange screws
from the breather cover. See Figure 8-35.
Figure 8-33. Removing Inner Baf es.
3. Disconnect and remove the oil temperature
sensor. See Figure 8-34.
NOTE: This is optional. Removing the oil
temperature sensor is not required to remove
the breather cover or inner ba es.
Figure 8-35. Remove Breather Cover Screws.
Pry Under
Edge
Hex Flange
Hex Flange
Screws
Screws