110
ENGINE STORAGE
- If the engine is not to be used for extensive periods, check the storage area condi-
tions and the type of packaging and make sure that these are suitable for correct
storage.
If necessary, cover the engine with a proper protective sheet.
- Avoid storing the engine in direct contact with the ground, in environments that are
humid and exposed to bad weather, near high voltage electric lines, etc.



PROTECTIVE TREATMENT
1 - Pour in the engine housing AGIP RUSTIA C protective oil up to the maximum level.
2 - Fill up with fuel containing 10% AGIP RUSTIA NT.
3 - Start the engine and keep it idle at minimum speed for some minutes.
4 - Bring the engine to ¾ of the maximum speed for 5÷10 minutes.
5 - Turn off the engine.
6 - Empty out completely the fuel tank.
7 - Spray SAE 10W on the exhaust and intake manifolds.
8 - Seal the exhaust and intake ducts to prevent foreign bodies from entering.
9 - Thoroughly clean all external parts of the engine using suitable products.
10 - Treat non-painted parts with protective products (AGIP RUSTIA NT).
11 - Loosen the alternator/fan belt (if present).
12 - Cover the engine with a proper protective sheet.




PREPARING THE ENGINE FOR OPERATION AFTER PROTECTIVE TREATMENT
After the storage period and before starting up the engine and preparing it for opera-
tion, you need to perform certain operations to ensure maximal efciency conditions.
1 - Remove the protective sheet.
2 - Remove any sealing devices from the exhaust and intake ducts.
3 - Use a cloth soaked in degreasing product to remove the protective treatment
from the external parts.
5 - Inject lubricating oil (no more than 2 cm3) into the intake ducts.
6 - Adjust the alternator/fan belt tension (if present).
7 - Turn the engine manually to check the correct movement and smoothness of the
mechanical parts.
8 - Rell the tank with fresh fuel.
9 - Make sure that the oil is up to the maximum level.
10 - Start the engine and after some minutes bring it to ¾ of the maximum speed for
5-10 minutes.
11 - Turn off the engine.
12 - Remove the oil drain plug (see “Oil replacement”) and discharge the AGIP RU-
STIA NT protective oil while the engine is hot.
13 - Pour new oil (see “Table of lubricants”) up to the maximum level.
14 - Replace the lters (air, oil, fuel) with original spare parts.


also based on age (see Replacement table).

