Residential/Light Commercial Generator Sets
Models:
24RCL
30RCL
38RCLB
Controller:
RDC2
TP-6905 7/18c
Operation

Table of Contents

Other manuals for Kohler RDC2

Questions and Answers

  • M
    michael92Sep 14, 2025
    Why is the LCD display off on my Kohler Inverter controller?
    • D
      Dustin BakerSep 14, 2025
      If the controller LCD display on your Kohler Inverter is off, it could be due to low or no battery voltage. Check the connections and the generator set battery.
  • P
    Pamela BrownSep 16, 2025
    What causes loss of communication to accessory modules on a Kohler Inverter?
    • N
      Nicole CrossSep 17, 2025
      If you are experiencing loss of communication to accessory modules on your Kohler Inverter, check the wiring and connections. Also, verify that the cable size and length comply with the instructions in the Installation manual. Low or no battery voltage can also cause this issue, so check the battery connections and the generator set battery.
  • M
    Mark HessNov 25, 2025
    Why Kohler Inverter cranks but does not start?
    • J
      Juan CarpenterNov 25, 2025
      If your Kohler Inverter generator set cranks but doesn't start, starts hard, lacks power, or operates erratically, several issues could be responsible. Begin by cleaning or replacing the air cleaner. Ensure the battery is adequately charged; recharge or replace it if weak or dead. Check and tighten the battery connections. Inspect the spark plug wire connections to ensure they are secure. Also, check for oil leaks, and verify the oil level, adding oil if needed. Insufficient fuel pressure could also be the cause, so check the fuel supply and valves. If the engine fuse is blown, replace it, but contact an authorized Kohler distributor/dealer if it blows again. If none of these steps resolve the issue, there might be an engine malfunction, requiring attention from an authorized Kohler distri...
  • C
    Christopher FloresDec 1, 2025
    Why does my Kohler Inverter generator set stop suddenly?
    • A
      amber99Dec 1, 2025
      Your Kohler Inverter generator set may stop suddenly due to several reasons: * Low oil pressure shutdown. Check for oil leaks and the oil level, adding oil if necessary. * Being out of fuel. Check fuel supply. * Overcrank shutdown. Reset the controller. If the overcrank fault occurs again, contact an authorized Kohler distributor/dealer. * Blown fuse(s). Replace the fuse. If the fuse blows again, contact an authorized Kohler distributor/dealer. * Overspeed shutdown. Reset the controller. If the overspeed fault occurs again, contact an authorized Kohler distributor/dealer. * The generator set is OFF. Press the RUN button to start the engine or press AUTO to allow remote starting. * Remote stop command received from a remote switch, ATS, or OnCuer. Check the remote switch posi...

Summary

Safety Precautions and Instructions

Accidental Starting

Procedures to prevent accidental generator set startup during maintenance.

Battery

Safety warnings and procedures for handling batteries, including acid and gases.

Engine Backfire;Flash Fire

Safety precautions related to fuel system, combustible materials, and exhaust.

Exhaust System

Warnings about carbon monoxide and safe operating areas.

Fuel System

Safety guidelines for handling, storing, and using fuels to prevent fire and explosion.

Hazardous Voltage;Moving Parts

Critical safety warnings about electrical hazards and moving components.

Hot Parts

Safety warnings for hot components like coolant, engine, exhaust, and alternator.

Section 2 Generator Set Operation

2.4 Generator Set Operation

Instructions for local and automatic starting/stopping, cooldown, and start cycles.

2.6 Faults

Information on identifying, classifying, and clearing warning and shutdown faults.

Section 3 RDC2 Controller Operation

3.1 RDC2 Generator Set;Transfer Switch Controller

Overview of the RDC2 controller's capabilities and managed components.

3.2 Controls and Indicators

Identification and function of the RDC2 controller's keypad, display, and LEDs.

Section 4 Scheduled Maintenance

4.1 General Maintenance

Safety precautions for performing maintenance tasks on the generator set.

4.2 Service Schedule

Table outlining routine maintenance checks, intervals, and procedures.

Section 5 Controller Troubleshooting

5.3 Fault Messages

How the RDC2 controller displays fault messages for troubleshooting.

5.5 Generator Set Troubleshooting

A chart listing common generator set problems, causes, and solutions.

5.6 Controller Troubleshooting

Troubleshooting guide for the RDC2 controller's display and functionality.

Kohler RDC2 Specifications

General IconGeneral
ModelRDC2
TypePortable Generator
Fuel TypeGasoline
Starting SystemRecoil
Voltage120 V
Outlet Types2 x 120V 20A GFCI Outlets