10 11
Owners Manual
6KK61BFA0 / 6KK92BCA3AA00
Frost prevenon
sensor and
Abnormal
temperature
sensor value
Refrigerant high
pressure switch
Abnormal
temperature
sensor value
Abnormal
temperature
sensor value
Evaporator motor
overload
(for 6KK92)
Drain pump
alarm
Indoor heat exchanger
temperature too low
TH3 temperature sensor
has a loose or broken
connecon
Blocked air filter
Blocked / kinked exhaust
duct
Ambient temperature
is too high
TH1(Outlet) temperature
sensor has a loose or
broken connecon
TH2(Inlet) temperature
sensor has a loose or
broken connecon
Drain pump defecve or
improper hose connecon
(including kink or blockage)
Ambient temperature is
too high
Unstable voltage supply
Defecve compressor
Abnormal operaon of
evaporator motor
(for 6KK92)
Abnormal operaon of
condenser motor
(for 6KK92)
Do not use the air
condioner if ambient
temperature is lower than
18°C (64°F)
Contact a qualified service
agent
Clean air filter
Ensure exhaust duct is not
blocked / kinked
Do not use the air
condioner if ambient
temperature is higher than
45°C (113°F)
Contact a qualified service
agent
Contact a qualified service
agent
Do not use the air condioner
if ambient temperature is
higher than 45°C (113°F)
Contact a qualified service
agent
Replace compressor
Contact a qualified service
agent
Check the hose connecon
and hose
Replace drain pump
SELF-DIAGNOSTIC ALARM CODES
Alarm
Display
ProblemCause Correcve Acon
Compressor
overload
Condenser motor
overload
(for 6KK92)
愚決檺律
;ΠΕΖΝ ΁ͽͲ΅ͶʹͲΆ΅ͺ΀Ϳ
΁Ͳ΃΅Ϳ΀
͵΃Ͳ;Ͷ΃ͺʹ΀΀ͽΈ΁ʹ
惾剳
岂憮斲決溎 Ω
惾剳殯Έ΁ʹ
洇殯微塾
沗昷 円皦 筛汾
朞洛斲穳
沲滎汆怺塶姷嵷滆惾畲嵦
汾曊愯憛樮廇汾
汾曊族旇籗族
祢彺熞庲岂惾嘪決砋΀΁΁瑚砋
汾曊匶渆壊彺愕昪凊洢击穊床
歾刃汞獞朞昦抏汆昦汆汾曊篊洎埮昦沊
ʹ΀怾割犚儆
Table 1- Alarm Codes