“Rev. incomplete” is displayed on the status bar (the
displayed torque signal is correct but the set
unscrewing is not complete).
next time you screw.
For 2AE model:
The error automatically resets next time you
screw.
“Pre-reverse incompl.” is displayed on the status bar
(the lever has been released before the Pre-Rev. has
been completed).
“Under min time” is displayed on the status bar (the
torque signal is displayed below the set minimum
time).
“Over maximum time” is displayed on the status bar
(the torque signal is displayed over the set maximum
time).
“Error PV torque” is displayed on the status bar (the
torque signal is displayed inside the set maximum
time).
“Below min torque” is displayed on the status bar
(the torque signal is displayed below the set
minimum time).
“Over max torque” is displayed on the status bar (the
torque signal is displayed over the set maximum
time).
“Compensation error” is displayed on the status bar
(the torque value is negative – this is due to an
excessively high negative compensation value)
- Set a higher/lower compensation value.
“Error unscrew torque” is displayed on the status bar
(The torque signal is displayed while unscrewing,
but only if it’s set on “max”).
- The screwdriver couldn’t unscrew.
- Avoid motor stalling.
- Unscrewing too heavy.
“Protection 12A” is displayed on the status bar (it
happens when current on mosfets of bridge H is >
12 A for at least 1 sec).
- Reduce cycle rate and check settings.
- Avoid motor stalling.
- Unscrewing too heavy.
- Joint too soft.
“Protection 14p5A” is displayed on the status bar (it
happens when current on mosfets of bridge H is >
14.5 A for at least 800 ms).
- Reduce cycle rate and check settings.
- Avoid motor stalling.
- Unscrewing too heavy.
- Joint too soft.
“Protection 15A” is displayed on the status bar (it
happens when current on mosfets of bridge H is > 15
A for at least 500 ms).
- Reduce cycle rate and check settings.
- Avoid motor stalling.
- Unscrewing too heavy.
“OUTPUT DISABLED” is displayed on the status
bar. It is on the protection of the output signals
exceeding the maximum load (400mA).
- Check that the load does not exceed the max
(400mA)
- To reset, restart the unit.