E-3
Adjustment Item Content of Function Initial Value Range Remark
Selection of the battery manufacture
Adjustment of BDI and discharge level of battery by
battery manufacture.
3 1 – 6
Battery manufacture
1:Reserve "A",
2:Reserve "B"
3:Shin-KOBE,GS-YUASA,HOPPECKE,
4:FAAM,
5:Global-B,
6:Reserve "F"
Materials Handling System Parameter Setting Function
Adjustment Item Content of Function Initial Value Range Remark
*
Custom (U): Materials Handling Power To set torque properties of travel power. 2
1: Low 2: Middle 3:
High
Initial Value L:2, M:2, H:3, U:2
*
Custom (U): Lift Speed To set lifting speed of mast.
100
(%)
1 - 100
(%)
1:Low 100:High
Initial Value L/M/H/U:100
*
Custom (U): Tilt Speed To set tilting speed of mast
100
(%)
1 - 100
(%)
1:Low 100:High
nitial Value L/M/H/U:100
ATT1 Speed To set attachment 1 speed.
50
(%)
1 - 100
(%)
1:Low 100:High
ATT2 Speed To set attachment 2 speed.
100
(%)
1 - 100
(%)
1:Low 100:High
ATT3 Speed To set attachment 3 speed.
100
(%)
1 - 100
(%)
1:Low 100:High
Lifting Shock-less Level
To set shock-less speed control level of mast when
stopped during lifting the mast.
3 0 - 7
0: Little shock
7: Big shock
Lowering Shock-less Level
To set shock-less speed control level of mast when
stopped during lowering the mast.
3 0 - 7
0: Little shock
7: Big shock
Lift Interrupt
To limit pump motor control output when BDI
shows below 20 %, warning operator to recharge
battery.
0 (Invalid)
0: Invalid
1: Valid